Permit Review Detail
Review Status: Stopped
Review Details: RESIDENTIAL BLDG/ZONING/FLOOD
Permit Number - T02CM00076
Review Name: RESIDENTIAL BLDG/ZONING/FLOOD
Review Status: Stopped
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/22/2002 | PATRICIA GEHLEN | ZONING | REVIEW | Approved | |
| 03/22/2002 | PATRICIA GEHLEN | NPPO | REVIEW | Passed | |
| 05/23/2002 | GERRY KOZIOL | WWM | REVIEW | Denied | |
| 05/23/2002 | DAVE WITT | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T02CM00076 5/22/02 3741 E. 33RD ST. PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. SCOPE OF REVIEW: THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2000 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL. GENERAL REQUIREMENTS: 1. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 2. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. FOUNDATION PLANS: 1. FOOTING WIDTHS FOR ONE-STORY, PER TABLE R403.1: - 16" MINIMUM; WOOD FRAME - 19" MINIMUM; HOLLOW CONCRETE/MASONRY - 22" MINIMUM; SOLID FULLY GROUTED/MASONRY 2. ALL SLABS AND PADS, INCLUDING LANDINGS AT ALL DOORS, SHALL BE SHOWN AND THEIR THICKNESS SPECIFIED. INDICATE THE SLOPE FOR EXTERIOR SLABS, PER R312. FLOOR PLANS: 1. LABEL ALL ROOMS AND SPACES . WHAT IS THE SMALL ROOM BESIDE THE BATH TUB. 2. PROVIDE ALL FIRE RATED WINDOWS LESS THAN 3 FEET FROM PROPERTY LINE. 3. PROVIDE ACCESS TO EACH SEPARATE ATTIC AND CRAWL SPACE THAT EXCEEDS 30SF. DESIGNATE LOCATIONS ON THE DRAWINGS. OPENINGS SHALL NOT BE LESS THAN 22" BY 30". THE ATTIC ACCESS SHALL PROVIDE A MINIMUM OF 30" OF HEADROOM, AND SHALL BE LOCATED IN A HALLWAY OR READILY ACCESSIBLE SPACE PER R807. 4. NOTE THAT SHOWER ENCLOSURES SHALL BE FINISHED PER p2710 WITH CERAMIC TILE, OR A LISTED ENCLOSURE, TO A HEIGHT OF 72" ABOVE THE DRAIN PER R702.4 AND R307.2 STRUCTURAL PLANS: 1. ROOF FRAME ,SEC. C-C , SPECIFY LINTEL. ELEVATIONS: 1. SPECIFY ROOF SLOPE. PLUMBING PLANS: 1. PROVIDE A VENT FOR THE SHOWER. 2. A BY-PASS VALVE IS NOT APPROPRIATE FOR THE W.H./FURNACE. 3. SIZE THE GAS LINES. 4. R307.2 REQUIRES THE SHOWER TO HAVE PROTECTED WALLS 72 INCHES ABOVE THE FLOOR. MECHANICAL PLANS: 1. HOW IS BEDROOM #2 HEATED? LIVINGROOM? 2. HOW DOES THE RETURN AIR COMPLY WITH I.R.C. M1602.3 ITEM 3 ? ELECTRICAL PLANS: 1. HOW DO THE SMOKE DETECTORS COMPLY WITH R317.1.1 ? 2. PROVIDE A RECEPTICLE WITHIN 6 FEET OF THE LATCH SIDE OF THE FRONT DOOR. MODEL ENERGY CODE: 1. PROVIDE ENERGY CALCULATIONS PER THE 1998 IECC, OR COMPLY WITH IRC CHAPTER 11. 2. CALL OUT ON THE PLANS THE "R" VALUES OF INSULATION, AS WELL AS THE "U" VALUES OF THE WINDOWS AND DOORS IN CONFORMANCE WITH THE ENERGY CALCULATIONS PROVIDED. IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: DAVID WITT @ 791-5550 EXT. 110 |
| 05/23/2002 | LLESNY1 | FLOODPLAIN | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 06/11/2002 | ELAINE ROSE | OUT TO CUSTOMER | Stop |