Permit Number: T02BU02990
Parcel: 10604191A

Address:
426 E MOHAVE RD

Review Status: Completed

Review Details: GRADING

Permit Number - T02BU02990
Review Name: GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/08/2003 JOE LINVILLE NPPO REVIEW Approved
01/08/2003 MSTPAUL1 NPDES REVIEW Passed
12/20/2002 PAUL MACHADO ENGINEERING REVIEW Denied DATE: December 20, 2002
To: Layton McHenry
Owner/Developer 2601 W. San Marcos
Tucson, Arizona 85713
SUBJECT: 426 E. Mohave Street
Grading Plan T02BU02990 (First submittal)
T13S, R13E, Section 25

RESUBMITTAL REQUIRED: Grading Plan and Drainage Report.

The Grading Plan (GP) and Drainage Report (DR) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Grading Plan:
1. Add note: "Depress all landscaped areas a maximum of 6" for water harvesting"
2. List administrative address/site address on plans.
3. List all Cut and Fill quantities in cubic yards. If both are 0 cy, please list.
4. Show the 100-year flood peak discharge.
5. Cut or fill slopes require a 2' minimum setback from property line.
6. Provide adjacent FFE for review of compliance Section 13 of the 2000 IBC concerning grade differential.
7. Call out peak discharges entering and exiting the site.
8. Dimension cross-section A-A.
9. Provide an elevation bench mark.

Drainage report:
1. List the FFE in the Drainage report.
2. Provide wall openings and the calculations for drainage on the East screen wall.
3. Please list the project address and activity number on the front cover of the drainage report and in all future cases as well.

If you have any questions, I can be reached at 791-5550, or pmachad2@ci.tucson.az.us
Paul Machado
Senior Engineering Associate
12/20/2002 ANY FLOODPLAIN REVIEW Denied Drainage report:
1. List the FFE in the Drainage report.
2. Provide wall openings and the calculations for drainage on the East screen wall.
3. Please list the project address and activity number on the front cover of the drainage report and in all future cases as well.
12/20/2002 PAUL MACHADO ENGINEERING REVIEW Denied Addition to original comments dated 12-20-02:
1. Show slope protection around building pads.
2. Engineer to provide pad certification against scouring.
3. Show limits and WSEL for the 10-year event.
12/20/2002 ANY FLOODPLAIN REVIEW Denied Addition to original comments dated 12-20-02:
1. Show slope protection around building pads.
2. Engineer to provide pad certification against scouring.
3. Show limits and WSEL for the 10-year event.
12/23/2002 DAN CASTRO ZONING REVIEW Denied Grading plan may not be approved until all other sections have approved the site plan and the grading plan

Final Status

Task End Date Reviewer's Name Type of Review Description
03/04/2003 ELAINE ROSE OUT TO CUSTOMER Completed