Permit Number: T02BU02975
Parcel: 133369570

Address:
60 N HARRISON RD

Review Status: Completed

Review Details: GRADING

Permit Number - T02BU02975
Review Name: GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/03/2003 PAUL MACHADO ENGINEERING REVIEW Approv-Cond To: E.A. Fagin & Associates
Architects
110 S. Church Ave.
Tucson, Arizona 85701
SUBJECT: 60 N. Harrison Road
Grading plan T02BU02975 (Second Review)
T15S, R15E, Section 11

RESUBMITTAL REQUIRED: Grading Plan

The Grading Plan (GP) cannot be approved as submitted. Please address the following review comments prior to the next submittal.

Grading Plan:

1. Call out the names of all washes (Wrightstown wash).
2. Show the 100-year flood peak discharge.
3. Drainage patterns with percent slopes (Show patterns within the first 100 feet from the property line).
4. Flow arrows, grades and flow rates within and adjacent to site to show drainage scheme.
5. Call out peak discharges entering and exiting the site.
6. Detention/Retention Basin:
ยท Cross-sections and dimensions. Where is section cross-section C-C of the basin shown on sheet C-2?
7. Show peak discharge at basin's outlet.
8. Provide soil protection for (5) rcp's outlet.
9. Why is there an outlet head wall for the bleeder pipe when the plans indicate gunite bank protection?

If you have any questions, I can be reached at 791-5550, or pmachad2@ci.tucson.az.us
Paul Machado
Senior Engineering Associate
02/03/2003 ANY FLOODPLAIN REVIEW Approved See engineering folder.
02/03/2003 PAUL MACHADO ENGINEERING REVIEW Approv-Cond To: E.A. Fagin & Associates Architects 110 S. Church Ave. Tucson, Arizona 85701


SUBJECT: 60 N. Harrison Road
Grading plan T02BU02975 (Third Review)
T15S, R15E, Section 11



RESUBMITTAL REQUIRED: Grading plan


Grading Plan:

1. The Grading plan is conditionally approved. Please re-submit the grading plan separately with their own sheet number, ie: sheet C1 and C2 only.


If you have any questions, I can be reached at 791-5550 x1193, or pmachad2@ci.tucson.az.us
Paul Machado
Senior Engineering Associate
02/12/2003 JOE LINVILLE NPPO REVIEW Approved
02/18/2003 LOREN MAKUS NPDES REVIEW Passed No Stormwater Pollution Prevention Plan is required at this time. Project will need to be in compliance with the AzPDES general permit once it is issued.
02/21/2003 DAN CASTRO ZONING REVIEW Denied Zoning Review Section may not approve the grading plan until Engineering has approved the grading plan.

Final Status

Task End Date Reviewer's Name Type of Review Description
03/13/2003 TAMI ACHONG OUT TO CUSTOMER Completed