Permit Number: T02BU02737
Parcel: Unknown

Review Status: Completed

Review Details: GRADING

Permit Number - T02BU02737
Review Name: GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
10/31/2002 LOREN MAKUS NPDES REVIEW Denied 1. Provide run-off coefficient for pr-construction conditions.
2. Include a copy of the permit requirements/language.
3. Provide for a log of dates that construction activities begin and end.
4. Provide for a log of materials stored on site.
5. Describe the required content for inspection reports.
11/04/2002 PATRICIA GILBERT NPPO REVIEW Denied A pre-permit inspection is required to check the transplants, the protective fencing for the NUOS area and the scenic buffer. To schedule please call 791-5640, ext. 1140.
11/05/2002 LAITH ALSHAMI ENGINEERING REVIEW Denied Laith Alshami, Engineering comments, 11/26/2002

1- Add the missing numbers in the Scenic Route Case Number (SCZ-XXX).
2- Show the location of cross-section 2/3. Additionally, the width dimensions are different from the approved Tentative Plat. Justify the changes.
3- The Grading Plan does not call for the hydroseeding the slope, shown in cross section 7/3, as required by the approved Tentative Plat. Justify the change.
4- Include the project administrative address on the cover sheet.
11/26/2002 MICHAEL ST. PAUL ZONING REVIEW Denied Engineering, Floodplain, NPDES and NPPO approvals required before Zoning review.
11/26/2002 LAITH ALSHAMI FLOODPLAIN REVIEW Denied Laith Alshami, Floodplain comments, 11/26/2002

1- Show the location of cross section 7/4. Include the slope percentage or ratio.
2- Show the location of cross section 1/4.
3- It has been the City's experience that grouted riprap with 6" mortar base does not last for long time which may require continious costly maintenace. We recommend increasing the thickness of the base.

Final Status

Task End Date Reviewer's Name Type of Review Description
11/26/2002 DELMA ROBEY OUT TO CUSTOMER Completed