Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: GRADING
Permit Number - T02BU02665
Review Name: GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/15/2002 | DAN CASTRO | ZONING | REVIEW | Denied | Grading plan may not be approved byt the Zoning Review Section until the site plan is approved. |
| 11/19/2002 | ANY | ENGINEERING | REVIEW | Denied | See flood plain comments. |
| 11/19/2002 | ANY | FLOODPLAIN | REVIEW | Denied | To: Steven Mitchell Durant Architects 2980 N. Campbell Ave. SUBJECT: 7200 E. Tanque Verde Road Site plan T02CM04760 (First Review) T14S, R15E, Section 05 RESUBMITTAL REQUIRED: Site Plan, Grading plan and Drainage Report. The Site Plan (SP) and Grading plan (GP) cannot be approved as submitted. Please address the following review comments prior to the next submittal. Site Plan: 1. Contingent on the planning dept. comment no. 2, if the building area expansion is 25% or greater, additional comments may be forth coming upon re-submittal. 2. Please provide property description per D.S. 2-02.2.1.3. 3. Please label lot dimensions and bearings per D.S. 2-02.2.1.5 4. Provide all existing and proposed buildings and structures, including location, size, height, overhangs, canopies, and use per D.S. 2-02.2.1.6. 5. Please label all vehicular, bicycle, pedestrian, and handicapped circulation clearly identified per D.S. 2-02.2.1.12. 6. Fully dimensioned loading space(s) and maneuvering area(s) per D.S. 2-02.2.1.14. 7. Please provide Drainage patterns and finished grades per D.S. 2-02.2.1.16. 8. Please list estimated cut & fill quantities per D.S. 2-02.2.1.17. 9. Please show dimensioned right-of-way, including any applicable Major Streets and Routes (MS&R) Plan right-of-way per D.S. 2-02.2.1.19. 10. Dimension from street monument lines to existing and proposed curbs, sidewalks, driveways, and utility lines per D.S. 2-02.2.1.21. 11. Location and orientation of existing major physical features, such as railroad tracks and drainageways per D.S. 2-02.2.1.22. 12. Please provide existing topograpghic contours at intervals not exceeding two (2) feet and/or spot elevations as pertinent and Bench Mark based on City of Tucson Datum, including City Field Book and page number per D.S. 2-02.2.1.23. 13. Show activity number on all sheets per D.S. 2-02.2.1.29. 14. Please show a typical cross section of the P.A.A.L. or call out the percentage of slopes. Call out the GB at the D/W, if applicable. 15. Please show the proposed roof drainage patterns, 100% of the 10-year flow must be conveyed under the sidewalks. Please provide supporting calculations to demonstrate compliance with D.S 3-01.4.4. 16. Add note regarding depressing all landscaped areas 6" maximum for water harvesting. 17. Show and fully dimension the det./ret. basin. 18. Install post barricades at back of side walk at the drop off location. 19. The keynote call out east of the new bldg. (no. 23) is not pointing to a tree and an arrow in the existing parking points to nothing. Please correct. 20. At the loading zone there is a key note call out (no. 28) that shouldn't be pointing to the loading zone. Please correct. 21. The key note call out (no. 27) is pointing to a door way not a berm. Please correct. 22. On the SP, the labels for the contour elevations are shown. Please show contours or since the GP is included the construction documents, the contour labels may be turned off. 23. Call out the steel plate lintel (no. 40) at the other location south, typical of the both. 24. Key note no. 41 is pointing to the det./ret. basin. Is this correct? If not revise. Grading plan: 1. Show and fully dimension the det./ret. basin. 2. Show activity number on all sheets per D.S. 2-02.2.1.29. 3. The GP does not match the drainage report in the basin area. 4. Add basin maintenance responsibility note to grading notes. 5. List the cut/fill on plans. 6. The Basis of elevation must include a Bench Mark based on City of Tucson Datum, including City Field Book and page number per D.S. 2-02.2.1.23. 7. Please show the proposed roof drainage patterns, 100% of the 10-year flow must be conveyed under the sidewalks. Please provide supporting calculations to demonstrate compliance with D.S 3-01.4.4. 8. Add note regarding depressing all landscaped areas 6" maximum for water harvesting. 9. In the southwest area of the fire lane, key note 4 is called out along with detail 9/C1.2 10. Call out the length of the depressed curb opening by the existing PAAL and by the loading zone. 11. There are two key notes that are relatively the same (no. 18 & no. 22). Please explain. 12. Where is key note 31 called out? 13. Should detail 2/C1.2 also call out an extruded curb? Can both conditions apply in different locations. Drainage Report: Is accepted and approved. On future submittals please list project address on the cover of all reports, studies, statements etc. If you have any questions, I can be reached at 791-5550 or pmachad2@ci.tucson.az.us Paul Machado Senior Engineering Associate, |
| 11/20/2002 | MSTPAUL1 | NPDES | REVIEW | Passed | |
| 11/20/2002 | JOE LINVILLE | NPPO | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/20/2002 | MONICA VALDEZ | OUT TO CUSTOMER | Completed |