Permit Review Detail
Review Status: Completed
Review Details: REVISION
Permit Number - T02BU02654
Review Name: REVISION
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/30/2003 | DOUG WILLIAMS | ENGINEERING | REVIEW | Denied | SUBJECT: Grading Plan Review -2 S. Panorama Ci. REVIEWER: Doug Williams DATE: 31 July 2003 ACTIVITY NUMBER: T02BU02654-R T14S, R13E, Section 15 SUMMARY: Engineering Division has performed a site visit and reviewed the revised "AS-Built" Grading plans received on 15 July 2003. A revised Site Plan (DSD activity # T03CM01570) must be submitted and approved in addition to the subject grading plan. Grading plan approval is not recommended at this time. Please address the following comments: GRADING PLAN COMMENTS: 1. Two of the three eastern retaining walls depicted on the plan have not been constructed, with the westernmost wall in place only. It is not clear whether the other two walls are to be constructed - please clarify. The site and grading plans call out 6 ' walls - field observation determined the constructed wall to be in excess of 10'. Revise the plans as necessary, depicting actual location and height of this retaining wall, and remove all other walls and references to such, if not to be constructed; 2. Revise Cross section A-A to reflect actual retaining wall construction, and omissions of other walls; 3. Include or reference conformance to excavation and grading requirements outlined in the 2000 International Building Code (IBC) - local amendment (chapter 36), in the Construction Notes section; 4. Please provide a copy of the soils engineering and geology report prepared for this site. The report must contain specific geotechnical recommendations for slope stability and treatments, should address interceptor drain recommendations or requirements, and address the proposed omission of the retaining walls depicted on the plan. Site grading not addressed in the report/recommendations should be in accordance with the guidelines listed in Chapter 36, 2000 IBC - with particular attention given to Sections 12 through 16; 5. The plan should clearly depict the limits of grading/construction; 6. There appears to be a wall depicted along the south property line on the plan. Please clarify this item or revise the plan accordingly; 7. Provide proposed parking (revision note # 4) cross sections and/or details, fully labeled and dimensioned; 8. Revise cut/fill quantities if necessary to account for all proposed revisions under this permit application. Please address all of the above comments. Resubmittal shall include a revised Site Plan and Grading Plan. If you have any questions, I can be reached at 791-5550, extension 1189 or Dwillia1@ci.tucson.az.us. Douglas Williams Sr. Engineering Associate Engineering Division Development Services Department Ref. T03CM01570/T03BU00408 |
| 08/11/2003 | PATRICIA GEHLEN | ZONING | REVIEW | Denied | Zoning 8/11/2003 Zoning will review and approve the grading plans once Engineering has approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 02/12/2004 | TAMI ACHONG | OUT TO CUSTOMER | Completed |