Permit Review Detail
Review Status: Completed
Review Details: GRADING
Permit Number - T02BU02553
Review Name: GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/16/2002 | BLANCA ESPINO | ENGINEERING | REVIEW | Denied | 1. Indicate Subdivision or Development Plan Number, Book and Page numbers. 2. Location map along with north arrow. 3. Re-calculate Cut and Fill quantities in cubic yards and note quantities on grading plan. 4. Indicate Limits of Grading, Floodplain Limits and all setbacks. 5. Indicate adequate spot elevations and contour lines. Contour line 2446 should not appear on the site as shown as per TDOT 2 foot contours. 6. Basis of elevation and basis of bearing - provide City of Tucson Bench Mark datum with field book & page number. 7. Call out contour interval. |
| 10/16/2002 | BLANCA ESPINO | FLOODPLAIN | REVIEW | Denied | SEE ENGINEERING FOLDER. |
| 10/17/2002 | CAGUILA1 | NPDES | REVIEW | Needs Review | |
| 10/17/2002 | CAGUILA1 | NPPO | REVIEW | Needs Review | |
| 10/17/2002 | CAGUILA1 | ZONING | REVIEW | Needs Review |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/17/2002 | LISA LESNY | OUT TO CUSTOMER | Completed |