Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL-BLDG/FIRE ONLY
Permit Number - T02BU02390
Review Name: COMMERCIAL-BLDG/FIRE ONLY
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/08/2002 | DCASTRO1 | FLOODPLAIN | REVIEW | Approved | |
| 10/14/2002 | JIM EGAN | FIRE | REVIEW | Denied | MINIMUM ONE-HOUR FIRE RESISTIVE RATED EXTERIOR WALLS REQUIRED FOR CARPORTS LOCATED LESS THAN 5 FEET FROM PROPERTY LINES. SEE 2000 IBC TABLE 602. |
| 10/23/2002 | DOUG LAAKSO | BUILDING-COMMERCIAL | REVIEW | Denied | ...T02BU02390 ......3201 E. FORT LOWELL ROAD. ...DGL . . .1. PROVIDE COMPLETED ' COMMERCIAL PLAN SUBMITTAL CHECKLIST' BY ARCHITECT, SEE ATTACHMENT.. ... ... ... . .............................................. . .2. PROVIDE COMPLETED 'CODE REVIEW CHECKLIST' ... . .3. DIMENSIONALLY LOCATE EACH CARPORT FROM ADJACENT PROPERTY LINES. . ................................. . . . 4. CLARIFY CARPORT DIMENSIONS ON SITE / ARCHTECTURAL PLAN. ................................................. . .5. DETERMINE OCCUPANCY 'S-2' OR 'U' PER IBC CHAPTER 3, SEC 302,311 AND 312, INDICATE ON DRAWINGS AND CODE REVIEW CHECKLIST. ......... . . ..... .6. ADDRESS AND SHOW COMPLIANCE WITH IBC SEC 406, ON DRAWINGS. ............................................. . . ....... . . . .7. NUMBER OR LETTER CARPORTS FOR IDENTIFICATION PUPOSES ON DRAWINGS / SITE PLAN. ...................... . . . .8. ADDRESS ALLOWABLE AND ACTUAL BUILDING AREA ON SITE PER IBC SEC 503 THROUGH 508, ON DRAWINGS AND CODE REVIEW CHECKLIST. .............................. . . . . .9. INDICATE TYPE OF CONSTRUCTION ON SITE PLAN AND CODE REVIEW CHECKLIST PER IBC SEC 6. ......... . . . 10. PROVIDE FIRE-RATED EXTERIOR WALLS WITH A FIRE-RESISTANCE RATING PER TABLE 602, MINIMUM, ON DRAWINGS, PROVIDE STRUCTURAL CALCULATIONS, DETAILS AND FIRE LISTING/S. .................................. . . . 11. ADDRESS ACCESSIBILITY PER IBC CHAPTER 11. .... . . 12. PROVIDE CROSS-SECTION OF THE CARPORT SHOWING ON DRAWING / SITE PLAN: ............................. ......1. HOW STRUCTURE/S RELATE TO PROPERTY LINE/S. .... . ............................................................. . .. . ......2. FLASHING OF WALL TO ROOF . .......................... . ......3. DETAILS OF FIRE-RATED WALL/S W/COPY OF FIRE LISTING/S ON DRAWINGS , SHOWING FOUNDATIONS, PROPERTY LINES, etc. ....................... . . 13. ADDRESS WALL TO CARPORT STRUCTURAL SUPPORT AND CONNECTIONS ON DRAWINGS AND IN STRUCTURAL CALCULATIONS AS WELL AS ARCHITECTURAL AND SITE PLAN. ........................... . . ............................................ .14. PROVIDE DOCUMENTS, INCLUDING DRAWINGS AND STRUCTURAL CALCULATIONS, WITH A MINIMUM OF TEN POINT FONT SIZE. ............................................. . . ... ... .15. SHOW STRESS INCREASES WHEN USED IN DESIGN ie: CALC PG #7 ( 3-#12SCREWS vs UPLIFT = 2.025 KIPS)... .16. SHOW PATTERN OF ROOF DECKING TO FASTENING TO SUPPORTS ON DRAWINGS. ................ ............... ..... .17. CLARIFY / COORDINATE COLUMN LOADS CALC SHEET #24 ( SDC = B vs SDC = C FOR THE PROJECT) ?... .18. PROVIDE INSPECTION PROGRAM PER 1994 UAC, SEC 302.5 AND IBC SEC 1704.1. .. ................... . . .............. .19. SPECIAL INSPECTION REQUIRED : ......................... . .......1. HIGH STRENGTH BOLTING. .................. . .......... . .......2. FIELD WELDING . ................................................. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/28/2002 | TAMI ACHONG | OUT TO CUSTOMER | Completed |