Permit Number: T02BU02144
Parcel: 115062140

Address:
1800 N STONE AV

Review Status: Completed

Review Details: GRADING

Permit Number - T02BU02144
Review Name: GRADING
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
08/19/2002 JIM TATE ENGINEERING REVIEW Denied The following items must be revised or added to the Grading Plan. Please include a letter with the next submittal addressing how all the engineering comments have been addressed.

1. A copy of the stamped approved Site Plan must be included with the Grading Plan submittal. Any changes made to the Site Plan must be reflected on the Grading Plan.

2. Retention basins can not be in the public right-of-way. If the areas designated as "retention" on the plan are actually water harvesting areas please change the labeling. The Drainage Report designates these areas as water harvesting areas with a depth of 6 inches. The Typical Water Harvesting Section Detail on Sheet 1 specifies the depth as 1 ft. This must be changed to a maximum of 6".

3. The Grading Plan shows curbing around the water harvesting areas. The Typical Water Harvesting Section does not show curbing. The Development Plan does not show curbing. Please make it clear on the Grading Plan that these areas are not curbed.

4. The water harvesting area west of Building 5 appears to encroach into the parking spaces.

5. The sidewalk on Stone does not appear to be located in the same place as on the Development Plan. The sidewalk should be located 2.5 ft. from the right of way (the 45-ft. ½ right-of-way as dedicated).
08/19/2002 MSTPAUL1 NPDES REVIEW Passed
08/19/2002 PATRICIA GILBERT NPPO REVIEW Denied Development plan approval is required prior to approval of grading plan.

Approved exception 7/23/02.
08/19/2002 JAMES TATE FLOODPLAIN REVIEW Approved
08/19/2002 MICHAEL ST. PAUL ZONING REVIEW Denied Engineering, Floodplain and NPPO.

Final Status

Task End Date Reviewer's Name Type of Review Description
09/19/2002 CINDY AGUILAR OUT TO CUSTOMER Completed