Permit Review Detail
Review Status: Stopped
Review Details: GRADING
Permit Number - T02BU01815
Review Name: GRADING
Review Status: Stopped
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/15/2002 | PAUL MACHADO | ENGINEERING | REVIEW | Denied | To: Gary Cretcher Cretcher Design, LLC 11261 E. Stampede Place Tucson, Arizona, 85749 SUBJECT: 1010 S. Harrison Road, Stockpile plan T02BU01815 (First Review) T14S, R15E, Section 28 RESUBMITTAL REQUIRED: Grading/Stockpile Plan The Stockpile Plan (SP) cannot be approved as submitted. Please address the following review comments prior to the next submittal. Stockpile Plan: 1. Show drainage patterns with percent slopes of stockpile area. 2. Sections of the stockpile area on sheet D1 are hard to read. Please address. 3. Flow arrows, grades, and flow rates within and adjacent to site to show drainage scheme. 4. Add spot elevations and/or contours. 5. Add plan scale and contour scale below north arrow. 6. A complete submittal of SWIPP is required. 7. List cut and fill quantities on plan. 8. List administrative address on plans. 9. Change title block to read "Stockpile plan" 10. Any grading in the right-of-way will require a separate permit. Contact Transportation at 791-4246 for information. 11. List Owner/Developer on plans. 12. List total square footage of area on plans. 13. Dimension future and existing right-of-way. 14. Area of stockpile not clearly defined. If you have any questions, I can be reached at 791-5550 or pmachad2@ci.tucson.az.us Paul Machado, Senior Engineering Associate, |
| 10/15/2002 | ANY | FLOODPLAIN | REVIEW | Approved | |
| 10/18/2002 | JOE LINVILLE | NPPO | REVIEW | Denied | An approved native plant preservation plan is required. In lieu that, the stockpile and grading could be allowed if there was no disturbance proposed to protected native plants. Revise plan to clearly demonstrate that all protected native plants will not be impacted by the temporary use. The native plant preservation plan (submitted seperately) is not approved. These plans should be picked up from the Landscape Section. |
| 10/28/2002 | LOREN MAKUS | NPDES | REVIEW | Denied | Stormwater Pollution Prevention Plan is required. |
| 10/31/2002 | MICHAEL ST. PAUL | ZONING | REVIEW | Denied | Engineering, NPPO and NPDES approvals required before Zoning review. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 11/12/2002 | ELAINE ROSE | OUT TO CUSTOMER | Stop |