Permit Review Detail
Review Status: Completed
Review Details: GRADING
Permit Number - T02BU00880
Review Name: GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/15/2002 | MATT FLICK | ENGINEERING | REVIEW | Denied | Engineering Comments: 1. A right-of-way permit is required for work within the public right-og-way. Contact the Tucson Department of Transportation (TDOT) at 791-5100 for permit and submittal requirements. The Development Services Department (DSD) doesn't issue permits for work within the public right-of-way. 2. Cut/fill quantities should be listed on the cover sheet. 3. Provide spot elevations in the detention basin. |
| 04/15/2002 | MATT FLICK | FLOODPLAIN | REVIEW | Denied | Floodplain: 1. Per Section 14.2.6 of the drainage standards manual (Dev. Std. 10-02.0.0), a soils report, in conformance with Section 14.2.6, is required. Part of said report will deal with the building setback from the basin. 2. Per Section 3.6.1 of the detention/retention manual (Dev. Std. 10-01.0.0), all detention basin floors must be graded to drain. Necessary detention/retention basin storage volumes must be maintained. |
| 04/16/2002 | MSTPAUL1 | NPDES | REVIEW | Passed | |
| 04/16/2002 | PATRICIA GILBERT | NPPO | REVIEW | Approved | Native plant preservation exception application approved via CDRC. |
| 04/16/2002 | MICHAEL ST. PAUL | ZONING | REVIEW | Denied | Engineering & Floodplain approval required. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/18/2002 | DELMA ROBEY | OUT TO CUSTOMER | Completed |