Permit Review Detail
Review Status: Completed
Review Details: GRADING
Permit Number - T02BU00174
Review Name: GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 02/22/2002 | DOUG WILLIAMS | ENGINEERING | REVIEW | Denied | Grading Plan: (1) Include sheet 7 in index. (2) Correct the north arrow on sheet 1. (3) Corrections in General notes #'s 12, 17, 21, 28, and 29 (see redlines). (4) Correct/revise overlapping contours on sheet 2 Provide dimensions for south basin callout 13/6 on sheet 2. (5) Provide reference or callout to sheet 7 (basin detail and offsite grading for berm) on northwest corner of site (sheet 3). (6) Include Improvement plan #'s, if available, for offsite improvements on sheets 4 and 5. (7) Provide % grades to west for three PAAL'S adjacent/south of pad #5, sheets 4 & 5 (indicated by redlines). (8) There appears to be a low spot (indicated by red's) on sheet 5, north of pad # 5 - revise grades or provide scupper. (9) Include sidewall bollards in detail 5/7, per Dev. Std. 6-01.1. (10) Provide dimensions for detail 13/7, whereas basin depth and width is relatively uniform for considerable distance(s). (11) Provide top/bottom of basin elevations and inlet detail, fully dimensioned, on sheet 7 (see redlines). (12) Provide written (notarized ?) permission for offsite grading. (13) Demonstrate compliance with water harvesting rezoning condition # 13. (14) Correct reference to 6" curb on detail 4/7 (8" curb typical). (15) The consultant should refer to section 13, chapter 36, 2000 IBC (differential grading criteria), and demonstrate compliance with the 4 conditions listed. Please note that only areas WITHIN the outer 100' OF THE DEVELOPING SITE are applicable. (16) Traffic Engineering Dev. Plan comments of 4/25/01 required maximum driveway widths of 35' (northernmost driveway - refer to Tucson Code, Chapter 25). Revise as necessary. - end. |
| 02/22/2002 | DOUG WILLIAMS | FLOODPLAIN | REVIEW | Denied | (1) Drainage report redlines should be addressed/noted - NO RETENTION IS BEING PROVIDED ON THIS PROJECT - DETENTION is however.... thus there appears to be no need for reference/calculations throughout the report for retention volume requirements/provisions. - end. (2) Page 13 discusses construction of a berm ..."at the northwest corner OF THE BASHA'S PROPERTY..." yet the berm is shown as being constructed offsite. Revise or note as necessary. (3) Correct the Q100 for CP 1 on page 14. |
| 02/28/2002 | LOREN MAKUS | NPDES | REVIEW | Denied | 1. Revise Location Map on SWPPP to show correct Swan Rd alignment. 2. Provide a description of the intended sequence of major activies. 3. Provide a schedule for the implementation of erosion and sediment controls. Include a description of when temporary controls may be removed. 4. In sections "Construction Management Practices" and "Erosion and Sediment Control Practices," describe specific practices and explain their implementation. 5. "Pollution Prevention Plan Certification" must be signed. 6. Show North arrow on SWPPP page 2. 7. Address timing of temporary and permanent stabilization of slopes along the western property boundary. 8. Describe stabilization practices that will be implemented on the slopes along the western property boundary. 9. Provide instructions for temporary stabilization of inactive areas. 10. Section "Post-Construction Stormwater Management" does not seem to apply to this project. |
| 02/28/2002 | DWILLIA1 | ZONING | REVIEW | Denied | Denied for ZRS (DW) |
| 03/01/2002 | PATRICIA GILBERT | NPPO | REVIEW | Denied | An approved site plan is required. Native plant preservation inspection is also required, to schedule please call 791-5550 ext. 140. Submit a NPPO plan with second submittal. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/12/2002 | DELMA ROBEY | OUT TO CUSTOMER | Completed |