Permit Number: T01OT01028
Parcel: 11108172F

Review Status: Completed

Review Details: SITE

Permit Number - T01OT01028
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
02/12/2002 DAVID RIVERA ZONING REVIEW Denied
03/06/2002 BLANCA ESPINO SANITATION REVIEW Denied
03/06/2002 BLANCA ESPINO ENGINEERING REVIEW Denied 1. Please revise the SVT's with appropriate lengths noted, 185' Near Side and 110' Far Side. D.S. 3-01.5.3

2. Refuse enclosures require gates for screening. Steel pipes are required for both the rear and side walls. The side walls pertain to the inner side of the side walls. Pipes are not required to be on the outer side of the enclosure. D.S. 6-01.4.2.B, 6-01.4.2.C.2
03/06/2002 BLANCA ESPINO FLOODPLAIN REVIEW Approved
03/07/2002 PHIL SEADER HANDICAP-SITE REVIEW Denied
03/08/2002 PATRICIA GILBERT LANDSCAPE REVIEW Denied On the landscape plan a 5' screen wall is proposed in a section of the street landscape border and not shown on the site plan. Please clarify. Refer to D.S. 2-07.2.1.A.

Screens are to be located on the development side of the street landscape border so that the landscaping is visible from the street. The wall must be constructed in a single continuous line and extends into a street landscape border no more than the actual width of the fence or wall. The proposed screen wall appears to be located 3 to 4 feet into the street landscape border. Please revise plan accordingly. Refer to LUC Sec. 3.7.3.2.C.

The trash enclosure must be screened from Haskell Drive with a gate that has the same characteristics as a wall (i.e. solid steel gate). Refer to LUC 3.7.2.I.

Revise the landscape plan as necessary to accommodate the changes with the SVT's. Refer to D.S. 2-07.

Decomposed granite is required in the right-of-way area along Haskell Drive between the property line and the street curb. Revise plan to show decomposed granite in the right-of-way. Refer to LUC Sec. 3.7.2.4.

The parking area must be screened from the property to the north with a 5' screen. Currently the plan depicts a 5' wall to screen the parking area from the north property, however the wall does not extend the entire length of the parking area. Please revise plan to extend the 5' wall the entire length of the parking area. Refer to LUC Sec. 3.7.2.I.

The planting plan should include both the proper and common name of each proposed planting. Currently, the planting legend only lists the genus of the proposed planting, Teucrium and Hibiscus. Please revise plan accordingly. Refer to D.S. 2-07.2.2.A.1.d.

Plant selection for landscaping is required to be from the Drought Tolerant Plant List found in the Development Standard 9-06.
03/08/2002 PATRICIA GILBERT NPPO REVIEW Denied Identify the native mesquites to be preserved on the landscape plan. Refer to 2-07.2.2.A.1.e.

Final Status

Task End Date Reviewer's Name Type of Review Description
05/20/2002 LISA LESNY OUT TO CUSTOMER Completed