Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T01OT00223
Parcel: 12003085B

Review Status: Completed

Review Details: C OF O

Permit Number - T01OT00223
Review Name: C OF O
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
07/12/2001 CHUCK STEPHENSON SIGNS REVIEW Approved
12/06/2001 PATRICIA GEHLEN ZONING REVIEW Approved
12/17/2001 REYES ARVAYO BUILDING-COMMERCIAL REVIEW Denied 2000 IRC RESIDENTIAL CHECKLIST

Date: 12-17-01
Re: Project No.T01OT00223

Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter backcheck time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating the action taken.

SCOPE OF REVIEW:

The scope of this review covers Architectural, Structural, Plumbing, Mechanical, Model Energy and Electrical codes. All code references are to the 2000 IRC. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

GENERAL REQUIREMENTS:

1. See attached sheets incorporate information on floor plan.

2. All corrections and revisions shall be made on the original tracings. Return all redlined prints. The final package shall consist of two sets of drawings and related documents, one which the City shall retain and the other set will be stamped and returned to you.

3. To avoid delays, ensure all corrections have been made, are complete and have been coordinated on all applicable details and notes.

4. List the square footages for the following areas separately on the drawings:
- Livable Area

FLOOR PLAN:

1. Provide all window sizes and types, and designate the operable portion of windows, as well as the locations of tempered glass per R308.4.

2. Show compliance with R310 providing egress from bedrooms:

a. Maximum sill height of 44".
b. Minimum net clear area of opening of 5.7 s.f.
c. Minimum net clear dimensions of opening of 24" height by 20" width.

3. Sprinkle system required on adult care facilities with 8 clients or more. Must be shown on separate drawing and approved by fire dept.

4. Two copies of drawings must be submitted -no pencil drawings .


REVIEWED BY REYES ARVAYO 791-5550 EXT. 110

Final Status

Task End Date Reviewer's Name Type of Review Description
02/28/2002 TAMI ACHONG OUT TO CUSTOMER Completed