Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T01OT00214
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/13/2001 | JIM EGAN | FIRE | REVIEW | Approved | |
| 07/23/2001 | MIKE BERGHUIS | FLOODPLAIN | REVIEW | Denied | Site lies in a COT-mapped flood hazard area |
| 07/23/2001 | MIKE BERGHUIS | ENGINEERING | REVIEW | Approved | |
| 07/23/2001 | MIKE BERGHUIS | SANITATION | REVIEW | Approved | |
| 07/30/2001 | PATRICIA GEHLEN | ZONING | REVIEW | Denied | CITY OF TUCSON DEVELOPMENT SERVICES DEPARTMENT ZONING REVIEW SECTION DATE: July 30, 2001 ACTIVITY NUMBER: T01OT00214 PROJECT NAME: Cavallino Construction PROJECT ADDRESS: 1227 & 31 East Knox Drive PROJECT REVIEWER: Patricia Gehlen The following items must be revised on or added to the site plan. Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed: 1) Minimum type size on a site plan is 12 point. Please increase the type size for the utility easement which runs between the proposed buildings, 2) In August of 2000, the Land Use Code vehicle parking required for multi-family residential was revised. Three bedroom units now require 2.25 spaces per unit. For this project, nine (9) spaces are required. Revise the calculations and site plan as required (DS 2-02.2.1.A.8, DS 2-02.2.2.A.4, LUC 3.3.4), 3) The four (4) northern most vehicle parking spaces require a back up spur and some type of physical barrier to prevent encroachment onto and over the pedestrian circulation system. Revise the site plan as required (DS 3-05.2.2.D, DS 2-02.2.1.A.11), 4) Revise the bicycle parking calculations as required based on comment 2 above (DS 2-02.2.2.A.4), 5) General note 2 must be revised to reference LUC 2.3.5.2.A.2 instead of LUC 2.3.5.2.A.1 since this is multi-family residential. In addition, add the existing use and development designator "K" to the general notes (DS 2-02.2.1.A.31), 6) The lot coverage calculation must be added to the site plan (DS 2-02.2.2.A.3, LUC 3.2.9). |
| 08/10/2001 | PHIL SEADER | HANDICAP-SITE | REVIEW | Approved | |
| 08/10/2001 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | Include the area from the property line to the the existing curb or edge of pavement in the note regarding decomposed granite. LUC 3.7.2.A Dimension the mountain Avenue landscape border. 50% vegetative groundcover is required. Revise plan as necessary. Revisions to the site plans must also be made to the landscape plan. 2-07 |
| 08/10/2001 | JOE LINVILLE | NPPO | REVIEW | Denied | Native Plant Preservation plan approval required. Submit plan or application for exception to LUC 3.8. |