Permit Number: T01CM05988
Parcel: 13707044A

Address:
5201 S 12TH AV

Review Status: Stopped

Review Details: RESUBMITTAL - SITE

Permit Number - T01CM05988
Review Name: RESUBMITTAL - SITE
Review Status: Stopped
Review Date Reviewer's Name Type of Review Description Status Comments
09/18/2002 DAN CASTRO ZONING REVIEW Denied COMMENTS: Provide a response letter with the next site plan submittal that states how all the Zoning Review Section comments were addressed.
CODE SECTION/ DEVELOPMENT STANDARD

1. A pedestrian easement must be provided for the portion of the public sidewalk along Utah Street which is located on private property. The easement must be recorded prior to site plan approval. Please provide a copy of the recorded easement and note the easement docket and page on the plan.
D.S. 2-02.2.1.A.20

2. Provide a disabled parking space detail which includes the access aisle and ramps.
D.S. 2-02.2.2.A.3

3. The City of Tucson Real Estate Division has requested that the future right-of-way along the 12th Avenue frontage be dedicated prior to site plan approval. Please contact Jim Stoyanoff at 791-4181 for further information regarding the dedication of the future right-of-way. Recordation information must be added to the site plan.

4. All requested revisions must be made to the site and landscape plans for consistency.
D.S. 2-07.2.1.A
09/18/2002 DAN CASTRO HANDICAP-SITE REVIEW Denied Refer to Zoning Review comment number two (2).
09/24/2002 JOE LINVILLE LANDSCAPE REVIEW Approved
10/10/2002 JIM TATE SANITATION REVIEW Approved
10/10/2002 JIM TATE ENGINEERING REVIEW Denied A Grading Permit is required.

TheDrainage Report was reviewed for Site Plan purposes only.

The following items must be revised or added to the site plan. Please include a response letter with the next submittal that states how all comments have been addressed.

1. The sidewalk on 12th Ave. must be specified as 6 ft. in width. Dimension the sidewalk location as 2.5 ft. from the future right of way. These are MS&R requirements.
10/10/2002 JAMES TATE FLOODPLAIN REVIEW Approved
10/11/2002 JIM EGAN FIRE REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
10/16/2002 DELMA ROBEY OUT TO CUSTOMER Stop