Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Number: T01CM05988
Parcel: 13707044A

Address:
5201 S 12TH AV

Review Status: Completed

Review Details: SITE

Permit Number - T01CM05988
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/14/2002 MIKE BERGHUIS ENGINEERING REVIEW Denied See yellow site review record. 1) Wall openings reqd per drainage rept 2)Keynote #14, see Zoning comments 3)Keynote #13 shows both SVT and Vert Curb- 4)Dimension UTAH ST curb to curb 5) Review new sidewalk loc along 12th, telecon E FAGIN on 1/14/02
01/14/2002 MIKE BERGHUIS FLOODPLAIN REVIEW Denied
01/14/2002 MIKE BERGHUIS SANITATION REVIEW Denied
12/11/2001 PHIL SEADER HANDICAP-SITE REVIEW Denied
12/12/2001 HPEARCE FIRE REVIEW Denied NEED INFORMATION ON FIRE RATING AND OPENING PROTECTION FOR SOUTH EXTERIOR WALL.
12/19/2001 DAN CASTRO ZONING REVIEW Denied COMMENTS: Provide a response letter with the next site plan submittal that states how all the Zoning Review Section comments were addressed. CODE SECTION/ DEVELOPMENT STANDARD

1. Since this site is comprised of two lots, they must be combined prior to approval of the site plan in one of the following ways: 1) the recordation of a new metes and bounds legal description, 2) the recordation of a new deed which names this site and lists all existing legal descriptions, 3) filing a Pima County tax combination form, or 4) the recordation of a covenant which runs with the land, stating that the existing lots function as one (1) and while the entire site may be sold, the individual parcels may not be sold separately without the permission of the City of Tucson, and signed by all owners. If number 4 is chosen, all existing lot lines must be shown on the site plan. All newly recorded documents must be submitted to the Zoning Review Section for review and approval prior to site plan approval and all applicable information (i.e. new legal descriptions and recordation information) must be added to the site plan.


2. Minimum font size required is 12. Revise plan as required.

3. a) Vehicle parking calculation must include the square footage of the public restrooms. Revise as required.
b) Dimension the length of the parallel parking spaces. In addition, keynote 14 pointing to the parallel parking spaces does not belong there, remove as required.
c) Revise the number of vehicle parking spaces provided under the vehicle parking calculation. The number provided should be the actual number located on the subject property.
D.S. 2-02.2.1.A.8/ D.S. 2-02.2.1.A.38/ D.S. 2-02.2.2.A.4

4. Clarify the location of the proposed six (6) foot high wall along the far south property line. No structure above 30 inches high may be located in a sight visibility triangle.
D.S. 2-02.2.1.A.10

5. If applicable, detail any existing and proposed free standing signage on the site plan.
D.S. 2-02.2.1.A.13/ D.S. 2-02.2.1.A.25

6. Dimension the length of the loading space on the site plan and indicate the size of the loading space required and provided under the loading space calculation.
D.S. 2-02.2.1.A.14/ D.S. 2-02.2.2.A.5

7. If applicable, provide the location, type, width, and recordation information of all existing and proposed easements on the site plan.
D.S. 2-02.2.1.A.20

8. Revise proposed F.A.R. to indicate correct number.
D.S. 2-02.2.2.A.3

9. a) Revise Utah Street setback required under the land use code block on sheet C-1 to state correct building setback required. Since the site is located along 12th, which is designated a Major Street and Route (MS&R), all abutting streets must meet the setback criteria listed under LUC 3.2.6.5.B.1.
b) Revise zoning classification note on site plan located east of the subject property from O-2 to 0-3.
D.S. 2-02.2.1.A.7/ L.U.C. 3.2.6.5.B.1

10. The copy of the last stamped approved site plan submitted indicates a total length of 155 feet for the property (lot 43a). The site plan indicates the lot is 90 feet long. Please demonstrate that this lot can function on its own (i.e. access and parking). In addition, the old site plan indicates a five (5) foot wide easement along the east property line. Has this been abandoned? Note the docket and page on the site plan.

11. All requested revisions must be made to the site and landscape plans for consistency.
D.S. 2-07.2.1.A
12/31/2001 JOE LINVILLE NPPO REVIEW Approved
12/31/2001 JOE LINVILLE LANDSCAPE REVIEW Denied A minimum 30" screen is required along all street frontages where the building does not abut the street landscape border. Add screening materials where necessary to provide a continuous opaque barrier. LUC Sec. 3.7.3.7; 3.7.3.3

Required screening may only be located within the street landscape border if the materials proposed encroach no more than 3 feet in to the border. Revise the plans to locate screening material at the development side of the street landscape borders. Sec. 3.7.3.2.C

One tree per every 33 linear feet is required within the street landscape borders. Trees planted within the adjacent right of way areas are not included in the calculation. Provide calculation for landscape border and number of trees required. Revise the plan to include the required number of trees within the landscape borders. Sec. 3.7.2.4

City Engineer approval is required in order to locate a portion of the required landscape border within the adjacent right of way. Provide verification of approval for portions of the 12th Avenue border. Sec. 3.7.2.4.A.2

Non-required landscaping placed in the right of way areas must be approved by the City Engineer in compliance with LUC 3.7.2.9. Provide verification of the required approval. Provide dimensions for the planter areas shown within the right of way areas.

Identify the screening requirements on the landscape plan and clearly show how the requirements are met (proposed heights, materials, locations). DS 2-07.

Final Status

Task End Date Reviewer's Name Type of Review Description
01/22/2002 ELAINE ROSE OUT TO CUSTOMER Completed