Permit Number: T01CM05805
Parcel: 13632011D

Review Status: Completed

Review Details: SITE

Permit Number - T01CM05805
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
12/04/2001 JIM EGAN FIRE REVIEW Approved
12/05/2001 PATRICIA GEHLEN ZONING REVIEW Denied
12/17/2001 PAUL MACHADO FLOODPLAIN REVIEW Denied
12/17/2001 PAUL MACHADO ENGINEERING REVIEW Denied 1. The property is located in flood plain AE. A flood plain use permit may be required. Please contact Flood Plain Engineering at 791-4914.
2. Please show sight visibility triangles, future and existing per D.S. 2-02.1.10.
3. Please show limits of the 100-year flood plain and water surface elevation per D.S. 2-02.1.15.
4. Please show all drainage patterns, proposed FFE, and finished grade elevations per D.S. 2-02.1.16.
5. List estimated cut and fill quantities per D.S. 2-02.1.17.
6. Show contour interval below north arrow and scale and a Bench Mark per D.S. 2-02.1.23.
7. Refuse container location, size and access per D.S. 2-02.1.32.
12/17/2001 PAUL MACHADO SANITATION REVIEW Denied
12/18/2001 PHIL SEADER HANDICAP-SITE REVIEW Denied
12/20/2001 JOE LINVILLE LANDSCAPE REVIEW Denied Locate the 30' scenic route buffer area based on the MS&R right of way line. Note that the area is to remain in a natural state.

It appears that a retention area is shown within the adjacent Houghton Road right of way. Is this a proposed or existing improvement? Any disturbed portion of the right of way adjacent to the scenic route buffer area must be revegetated with native plants. LUC 3.7.5.2
A revegetation/landscape plan may be required.

Additional comments may apply pending verification of legal non conforming status.
12/20/2001 JOE LINVILLE NPPO REVIEW Denied A native plant preservation plan/exception submittal may be required if improvements are proposed within the right of way.

Pending verification of legal non conforming status, native plant preservation requirements for the site cannot be determined.

Final Status

Task End Date Reviewer's Name Type of Review Description
12/28/2001 MONICA VALDEZ OUT TO CUSTOMER Completed