Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING/FLOOD
Permit Number - T01CM05765
Review Name: RESIDENTIAL BLDG/ZONING/FLOOD
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/27/2001 | PETER MCLAUGHLIN | ZONING | REVIEW | Approved | |
| 11/27/2001 | MATT FLICK | FLOODPLAIN | REVIEW | Approved | |
| 11/27/2001 | PETER MCLAUGHLIN | NPPO | REVIEW | Passed | |
| 12/17/2001 | REYES ARVAYO | BUILDING-RESIDENTIAL | REVIEW | Denied | 2000 IRC RESIDENTIAL CHECKLIST Date: 12-17-01 Re: Project No. T01CM05765 Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. SCOPE OF REVIEW: The scope of this review covers Architectural, Structural, Plumbing, Mechanical, Model Energy and Electrical codes. All code references are to the 2000 IRC. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. SITE PLAN 1. Indicate the location of, water, electric and sewer or lines on the property, and where they enter the new addition . Provide the location of your water meter FOUNDATION PLAN: 1. Dimension the stem wall thickness, footing width thickness and depth into undisturbed soil for each footing type and condition, per Table R403.1. - 16" minimum; conventional light frame/wood/metal 2. All foundation hold downs and anchor bolt spacing for shear walls shall be specified and located. FLOOR PLAN: 1. Note that bath tub and shower enclosures shall be finished per P2710 with ceramic tile, or a listed enclosure, to a height of 72" above the drain per R702.4 and R307.2. 2. Locate and identify shear wall types and locations. STRUCTURAL PLANS: 1. Specify design criteria on plans: Values for floor dead load and live load, roof dead load and live load. 2. Provide bracing details and notes for exterior frame walls and main cross-stud partitions, or use fully-braced, per R602.10.3. A minimum panel width of 48" is required to effectively brace the partition. See Table R602.10.3, Category "C". If bracing does not comply, provide a lateral analysis or alternate design to be reviewed by the plans examiner. Wind forces for single story residences shall use 90 mph, Side of addition where window and door are located PLUMBING PLANS: 1. Note on plans: Plumbing shall comply with Chapters 24 through 30.. 2. Note and specify all piping materials. 3. Water Lines: Provide total fixture demand and maximum developed length per P2903, Tables P2903.6 and P2903.7. include existing fixture if applicable 4. Specify compliance with water conservation: water closets 1.6 gallons per flush, sinks and shower heads 3 gallons per minute , per ARS. 5. Provide pressure and temperature relief valve at water heater, per P2803. MECHANICAL PLANS: 1. Note on plans: Mechanical shall comply with Chapters 12 through 24, 2000 IRC. 2. The dwelling must be provided with heating capable of maintaining a room temperature of 68 degrees at a point 3' above the floor, per R303.6. size of unit MODEL ENERGY CODE: 1. Provide Energy Calculations per IECC, or comply with IRC Chapter 11. 2. Call out on the plans the "R" values of insulation, as well as the "U" values of the windows and doors in conformance with the energy calculations provided. REVIEWED BY REYES ARVAYO 791-5550 ETC. 110 |
| 12/20/2001 | GERRY KOZIOL | WWM | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/08/2002 | DELMA ROBEY | OUT TO CUSTOMER | Completed |