Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T01CM05582
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/08/2002 | JIM EGAN | FIRE | REVIEW | Approved | |
| 03/14/2002 | PATRICIA GEHLEN | ZONING | REVIEW | Denied | CITY OF TUCSON DEVELOPMENT SERVICES DEPARTMENT ZONING REVIEW SECTION DATE: March 14, 2002 ACTIVITY NUMBER: T01CM05582 PROJECT NAME: Enterprise Rent-a-Car PROJECT ADDRESS: 5440 East Speedway Blvd. PROJECT REVIEWER: Patricia Gehlen The following items must be revised on or added to the site plan. Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed: 1) Per general note #21, this site is made up of two lots. The lots must be combined using the attached Pima County Tax Combo form and affirmation. The legal descriptions must be attached to the affirmation and all pages recorded. A copy of all processed and recorded documents must be provided with the resubmittal of these plans. The recordation information must be added to the site plan adjacent to the legal description. The attached Pima County combo form has not been processed and the recorded affirmation with legal descriptions has not been provided (DS 2-02.2.1.A.2), 2) The height of the metal parking canopy must be added to the plan. Since the parking under the canopy is counted as provided parking, the spaces must be fully dimensioned. Also, pedestrian circulation may not be located behind a parking stall as shown. It is too dangerous. Please revise as required, 3) The setbacks listed in general note #4 must be revised. The street setback is "the greater of 21 feet or the height of the structure from back from future curb" (LUC 3.2.6.5) and the south setback is the 1.5(H) of the proposed structure (60 feet based on a 40 foot building height). The rear setback on the plan is 24 feet and must be revised to 60 feet. Revise general note 4 to state a rear yard setback of 60 feet (DS 2-02.2.1.A.7, LUC 3.2.6.4), 4) Per a telephone conversation with the client, it was determined that the principal use of this site is "office" since most of the GFA will be used as the regional office for Enterprise Rent-A-Car and very little car rental will occur on this property. In addition, no rental cars will be stored on site. Revise general notes 3, 6, and 7 as required (DS 2-02.2.1.A.8), 5) There are walls adjacent to the existing metal canopy which conflict with a proposed PAAL (and possibly the roof). The walls must be removed (and a note added to the site plan to that effect) or the PAAL location revised, (DS 3-05.2.3.C, DS 2-02.2.1.A.8), 6) The bicycle parking calculations must be revised to be based on the proposed office use. A fully dimensioned detail of the parking spaces must be provided (DS 2-02.2.1.A.9, DS 2-09, DS 2-02.2.2.A.4, and LUC 3.3.4), 7) Revise the conflict of use on the site plan. The vehicle and bicycle parking is based on vehicle leasing and the loading zones are based on an office use. See additional comments above, 8) The continuous on-site pedestrian circulation system must continue to the existing building in the southwest corner of the site. The system must be raised concrete where it does not cross a vehicle use area. In addition, it may not be located behind a vehicle parking space for safety reasons. The sidewalk along the east side of the existing building must connect to the on-site system (DS 2-08). |
| 03/22/2002 | JOE LINVILLE | LANDSCAPE | REVIEW | Approved | |
| 04/10/2002 | ANY | FLOODPLAIN | REVIEW | Approved | |
| 04/10/2002 | PAUL MACHADO | ENGINEERING | REVIEW | Approved | SUBJECT: Enterprise Rent a Car, T01CM05582 SITE PLAN (Second Review) T-14-S, R-14-E, Section 11 RESUBMITTAL REQUIRED: NONE All comments have been addressed and the project approved. If you have any questions, I can be reached at 791-5550 or pmachad2@ci.tucson.az.us |
| 04/10/2002 | ANY | SANITATION | REVIEW | Approved | |
| 04/10/2002 | PHIL SEADER | HANDICAP-SITE | REVIEW | Denied |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/11/2002 | TAMI ACHONG | OUT TO CUSTOMER | Completed |