Review Date Reviewer's Name Type of Review Description Status Comments
11/14/2001 JIM EGAN FIRE REVIEW Approved
11/30/2001 DAVID RIVERA ZONING REVIEW Denied TO: Mark Bollard, Swaim & Associates
3936 E. Fort Lowell Rd. Ste. No. 202
Tucson, AZ 85712
(520) 326-3700

FROM: David Rivera
Senior Planner
FOR: Patricia Gehlen
Principal Planner

PROJECT: T01CM05560
2002 N. Greasewood Road
New Church Development
Site Plan Review (1st review)

TRANSMITTAL: November 30, 2001

COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed.

1. Please add to sheet SD-1, the legal description of the property. DS 2-02.2.1.A.2

2. The location map should include the section, township, and range. DS 2-02.2.1.A.4

3. The lot dimensions and bearings must be added to sheet SD-1. DS 2-02.2.1.A.5

4. Please list the use of the rooms annotated just as "rooms". If they are to be classrooms annotate as such. If they are rooms used for religious services they must be annotated as such and additional parking will be required. Revise as required. DS 2-02.2.1.A.6

5. The maximum building height allowed is 25 feet. The building height as indicated on the elevation drawings is 27'-4 3/8". The building height for zoning requirements is measured from finished grade. Add a finish grade elevation to sheet A2.1. For this development the building height requirements would be measured to the midpoint of the gable as noted on sheet SD-1. However the uninhabitable ornamental element is measured from the 25 feet elevation as measured from finished grade and may not exceed 10 feet in height. The ornamental element is proposed at a maximum of 15'-5". The height of the ornamental element and the maximum height of the roof ridge equal approximately 42'-9" plus the height from the finished grade to finish floor. The maximum height that is allowed per the LUC is 35' from finished grade. See LUC section 3.3.7.2 for vertical building height measurement and LUC 3.2.7.3 regarding ornamental elements. Revise as required. DS 2-02.2.1A.6

6. The vehicle parking calculation must be revised to include the number of vehicle parking spaces provided. The bicycle parking calculation must be revised to include the number of required and provided bicycle parking spaces. The bicycle parking calculation is based the total number of vehicle parking spaces provided. Revise both calculations as required.

All vehicle parking spaces that abut a pedestrian sidewalk, landscape border, or property line must be provided with wheel stops which must be located two and one-half (2-1/2) feet from the front of the parking space. Add wheel stops to the vehicle parking spaces or provide a detail drawing indicating the dimensions and the wheel stops. Revise as required. DS 2-02.2.1.A.8 & .9

7. Add the future sight visibility triangles at both PAAL entrances based on the future right-of-way cross section. The future curb location for Greasewood Road is 12 feet from the future property line. The total right-of-way for Greasewood will be 150 feet with a 75 feet half right-of-way.
DS 2-02.2.1.A.10

8. Dimension the concrete sidewalks. All sidewalks must be a minimum of four (4) feet wide unless a vehicle parking space without a wheel stop abuts the sidewalk in which case the sidewalk must be six and one-half (6-1/2) feet wide. Revise as required.

Directional signage to the bicycle parking facility must be provided when the facility is not visible from the street. The bicycle facilities on this site are not visible from the street. Provide directional signage and annotate as such. Dimension the bicycle parking facilities as required per development standards 2-09. DS 2-02.2.1.A.12

9. If applicable indicate on the site plan the location of all existing or proposed freestanding signs. The location, type and size must be indicated. DS 2-02.2.1.A.13

10. Clarify who is allowed to use the existing access easement. Provide a copy the recorded easement with the next submittal. DS 2-02.2.1.A.20

11. Add the zoning classifications adjacent to the parcel. The zoning classifications for the adjacent parcels are R-1 to the north, west, south, and east. DS 2-02.2.1.A.28

12. Clarify if the areas designated as rooms are for a charter school, Sunday school classes, bible study classes etc. If the rooms are for a charter school, additional comments may be forthcoming with review of the next site plan submittal.
DS 2-02.2.1.A.31

13. Revise the lot coverage calculation to include the square footage of the building area, the storage shed, and the vehicular use area.

Revise all calculations as required. DS 2-02.2.2.A.1-.6

14. All changes made to the site plan sheets must be made to the landscape plan sheets for consistency.
12/07/2001 PAUL MACHADO FLOODPLAIN REVIEW Denied
12/07/2001 PAUL MACHADO ENGINEERING REVIEW Denied
12/07/2001 PAUL MACHADO SANITATION REVIEW Denied
12/18/2001 JOE LINVILLE LANDSCAPE REVIEW Denied An appropriate inorganic material, such as decomposed granite, is required for the area between the property lines and the adjacent streets. Revise the landscape plan to include appropriate materials for these areas. LUC 3.7.2.4.A.3

City Engineer approval is required for landscaping proposed in the right of way areas. Please obtain necessary approval and
include verification with future submittals. LUC 3.7.2.4.A.2

Please dimension the street landscape borders. When the street landscape border exceeds the minimum 10 foot requirement, the border width is necessary to determine the 50% coverage calculation. Include calculations for coverage or revise plan as necessary to demonstrate compliance. DS 2-06.3.4.C.2, LUC 3.7.2.4.A.4.

The Landscape Plan and the Native Plant Preservation require coordination. Add the required summary of required native plants to the Landscape Plan and show the locations of preserved in place plants. DS 2-15.3.4.B.2, 2-07.2.2.A.1.e
12/18/2001 JOE LINVILLE NPPO REVIEW Denied The NPPO submittal requires revision as follows:

Tagging and Flagging Standards must be included per DS 2-15 5.0 and 2-15.6.0
12/19/2001 PHIL SEADER HANDICAP-SITE REVIEW Denied

Final Status

Task End Date Reviewer's Name Type of Review Description
12/20/2001 MVALDEZ1 OUT TO CUSTOMER Completed