Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T01CM05440
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/02/2001 | JIM EGAN | FIRE | REVIEW | Approved | |
| 11/21/2001 | PATRICIA GILBERT | LANDSCAPE | REVIEW | Denied | All replacement plants which are used on site to satisfy the mitigation requirements of the provisions of LUC 3.8, shall be planted in locations to support there long term health and survival and shall be planted in densities and configurations to approximate the natural chararcter of the Sonaoran Desert. Please indicate on the landscape plan the location of the required replacement plants. Refer to LUC 3.8.6.6. |
| 11/21/2001 | DAN CASTRO | ZONING | REVIEW | Denied | COMMENTS: Provide a response letter with the next site plan submittal that states how all the Zoning Review Section comments were addressed. CODE SECTION/ DEVELOPMENT STANDARD 1. a) The proposed use "Distribution System" is not an allowed principal use under the SR zone although it is allowed as a special exception land use which requires approval through a Type V Administrative Procedure. Approval of the special exception land use is required before the site plan may be approved. Refer to L.U.C. sec. 5.4.3.5 for information regarding the Type V Administrative Procedure. This review is based on criteria listed under the Distribution System use. b) The proposed use is "subject to" L.U.C. sections 3.5.11.1.A, .B, .E, .H, .I, and .K. Add a general note which lists the proposed use and the applicable "subject to" sections and demonstrate compliance with all "subject to" sections on the plan. One of the "subject to" requires review by the Development Review Board (DRB). D.S. 2-02.2.1.A.31; L.U.C. 5.4.3.5 2. List the height of the control building, fence, and antenna on the project plan on sheet 2 of 15. D.S. 2-02.2.1.A.6 3. a) Per L.U.C. 3.3.4 "Utilities Use Group: Distribution System", a minimum of two (2) vehicle parking spaces is required for this facility. Please label and fully dimension the two (2) required vehicle parking spaces on the plan and add a general note which states the number of vehicle parking spaces required and provided. b) All vehicle use areas must be a minimum of double shot chip seal. D.S. 2-02.2.1.A.8; L.U.C. 3.3.4; D.S. 2-02.2.2.A.4; L.U.C. 3.3.7.3 4. Dimension PAAL width on site plan. Minimum width for two-way traffic is 24 feet. D.S. 2-02.2.1.A.11; L.U.C. 3.3.7.2 5. Continuous pedestrian circulation required. D.S. 2-02.2.1.A.12; L.U.C. 3.2.8.4.B 6. If applicable, all existing or proposed easements must be shown on the plan including width, type, and recording docket and page reference. D.S. 2-02.2.1.A.20 7. All requested changes must be made to the site and landscape plans. D.S. 2-07.2.1.A |
| 11/26/2001 | DOUG WILLIAMS | ENGINEERING | REVIEW | Approved | |
| 11/27/2001 | DOUG WILLIAMS | FLOODPLAIN | REVIEW | Denied | |
| 11/27/2001 | DOUG WILLIAMS | SANITATION | REVIEW | Approved | |
| 12/04/2001 | PATRICIA GILBERT | NPPO | REVIEW | Denied | The proposed Acacia Greggii (Catclaw Acacia) to be removed from site has a truck caliper of 4". The proposed replacement size on the planting legend is 5 gallons. The required replacement size for trees with a 4" caliper is a 15 gallon container size. Refer to LUC 3.8.6.2.C., table 3.8.6-I. and 3.8.6.6. |
| 12/05/2001 | PHIL SEADER | HANDICAP-SITE | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/06/2001 | LLESNY1 | OUT TO CUSTOMER | Completed |