Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Number: T01CM05396
Parcel: 117060690

Address:
435 E 9TH ST

Review Status: Completed

Review Details: REVISION

Permit Number - T01CM05396
Review Name: REVISION
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/21/2004 Linda Buczynski ELECTRICAL-COMMERCIAL REVIEW Denied TRANSMIT ORIGINAL DRAWINGS WITH NEXT SUBMITTAL.

PLEASE CALL AT 791-5550 X1106 OR EMAIL AT Linda.Buczynski@tucsonaz.gov
IF YOU CARE TO DISCUSS.

1. Please update lighting energy calculations. The current ASHRAE 90.1 that the City enforces is 2001, effective July 1, 2004.
2. Provide maintenance receptacle on roof for heat pumps.
3. Per Sheet M3, HP-2, HP-3, and HP-4 operate at 3-phase power. Mezzanine Level Power Plan and Panel MD schedule call for single phase power. Coordinate with Mechanical and clarify.
4. Per Sheet M3, MOPD for HP-2 and HP-3 is 40. Electrical calls for fusing at 60A and 70A CB. Coordinate with Mechanical and clarify.
5. Per Sheet M3, MOPD for HP-4 is 35. Electrical calls for fusing at 25A. It might be appropriate to verify that this level of protection will allow the motor to start.
6. It appears that Ckt B-1 should have 1500 VA (includes continuous load) instead of 600 VA.
7. It appears that Ckt B-2 should have 1875 VA (includes continuous load) instead of 600 VA.
8. It appears that Ckt B-3 should have 1500 VA (includes continuous load) instead of 600 VA.
9. It appears that Ckt B-4 should have 1875 VA (includes continuous load) instead of 600 VA.
10. It appears that Ckt B-5 should have 1143 VA (includes continuous load) instead of 760 VA.
11. It appears that Ckt B-6 should have 1125 VA (includes continuous load) instead of 300 VA.
12. It appears that Ckt B-8 should have 975 VA (includes continuous load) instead of 700 VA.
13. It appears that Ckt B-10 should have 2250 VA (includes continuous load) instead of 570 VA.
14. It appears that Ckt A-39 should have 900 VA (includes continuous load) instead of 540 VA.
15. It appears that Ckt A-41 should have 900 VA (includes continuous load) instead of 540 VA.
10/04/2004 Raul Palma BUILDING-COMMERCIAL REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
10/07/2004 LISA LESNY OUT TO CUSTOMER Completed
10/07/2004 ANGIE SHOFFSTALL REJECT SHELF Completed