Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: SITE
Permit Number - T01CM05288
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 10/26/2001 | JIM EGAN | FIRE | REVIEW | Approved | |
| 10/29/2001 | BLANCA ESPINO | FLOODPLAIN | REVIEW | Denied | |
| 10/29/2001 | BLANCA ESPINO | ENGINEERING | REVIEW | Denied | D.S. 2-02.2.1 Site Plan 1. 4. A Location Map needs to be on the Site Plan having the section, township and range; section corners; north arrow; and a scale of 3" = 1mile. 2. 17. Estimated cut and fill quantities needs to be noted if applicable or not. 3. 21. Dimension existing and proposed sidewalks. Please identify the "T" west of the Loading Zone. 4. Restaurants and other food service establishments are required to provide a sewer-connected drain in the center of the slab to facilitate container cleaning. As per D.S. 6-01.4.2.C.1. |
| 10/29/2001 | BLANCA ESPINO | SANITATION | REVIEW | Denied | |
| 11/16/2001 | DAVID RIVERA | ZONING | REVIEW | Denied | |
| 11/16/2001 | PATRICIA GILBERT | LANDSCAPE | REVIEW | Denied | Include location map and legal description on the landscape plan. Refer to 2-07. Based on the Major Street and Route Plan for the 150' future ROW 3.5' is available for landscaping. City Engineering approval is required for any portions of the ROW proposed to meet the landscape border requirement. Clearly depict how the development will comply with the LUC requirements when the MS&R ROW can no longer be used as part of the site. Please clearly depict the dimensions of the future sidewalk and landscaping, Refer to LUC 2.8.3.5. and 3.7.2.4. A minimum of one canopy tree must be provided within a required landscape border. For a street landscape border a canopy tree every 33 linear feet of the landscape border or a faction thereof is required, excluding the ingress/egress points. The proposed street landscape border along Campbell Ave currently does not depict canopy trees in the street landscape border. Please revise plan accordingly. Refer to LUC 3.7.2.4. Along Campbell Ave. a Major Street and Route (MS&R), a 30" screen is required for commercial property adjacent to an MS&R street. Please refer to LUC 3.7.3. and 3.7.2.I. A 6' masonry screen wall is required for the proposed trash enclosure and loading area. A 5' masonry screen wall is required for vehicular parking. Please revise plan accordingly. Refer to LUC 3.7.3. and 3.7.2.I. Depict locations, height and type of screening material on the landscape plan. Refer to 2-07.2.2.A.3. Depict the size and species of the existing tree proposed to remain on site. Refer to 2-07.2.2.A. Indicate how the development will make maximum use of stormwater for on-site supplemental irrigation purposes. Refer to DS 2-07.2.2.B.6., LUC 3.7.4.3.B. and 3.7.4.5.B. Decomposed granite or other appropriate inorganic groundcover material is required between the property line and the back of the sidewalk and the sidewalk and back of street curb. Please revise plan accordingly. Refer to LUC 3.7.2.4.A.3. Should changes/amendments to the base/site plan occur through the review process, the same changes/amendments will be made to the landscape plan when resubmitted. Refer to DS 2-07.2.1.A. Additional comments could be made on the second submittal. |
| 11/27/2001 | PATRICIA GILBERT | NPPO | REVIEW | Denied | Please submit a native plant preservation plan or an exception application. For the native plant preservation requirements please refer to LUC 3.8. and DS 2-15. See attached documents. |
| 11/29/2001 | PHIL SEADER | HANDICAP-SITE | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/03/2001 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |