Permit Number: T01CM05246
Parcel: 11904609A

Address:
438 W AJO WY

Review Status: Completed

Review Details: SITE

Permit Number - T01CM05246
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
01/17/2002 PHIL SEADER HANDICAP-SITE REVIEW Approved
11/07/2001 JIM EGAN FIRE REVIEW Approved
11/20/2001 DAVID RIVERA ZONING REVIEW Denied
12/04/2001 BLANCA ESPINO SANITATION REVIEW Approved
12/04/2001 BLANCA ESPINO ENGINEERING REVIEW Approved 1. Please add bearings to lot dimensions.

2. Existing and future sight visibility triangles need to be labeled with appropriate lengths.

3. Location, type, size and height of existing and proposed signage if applicable.

4. 1Fully dimensioned loading space(s) and maneuvering area(s), please note if applicable.

5. Limits of the 100-year floodplain and water surface elevation (when applicable).

6. Drainage patterns, proposed finish floor elevation(s) and finish grades.

7. Dimensioned right-of-way, including any applicable Major Streets and Routes (MS&R) Plan right-of-way. The intersection Ajo/12th is a widening intersection. Therefore both streets widen to 150' by 300' both directions then taper off 300' into the existing R.O.W. MS&R pages 8 &9.

8. Dimension from street monument lines to existing and proposed curbs, sidewalks, driveways and utility lines.


Drainage Report
1. A drainage report is required for Balanced Basin areas.
12/04/2001 BLANCA ESPINO FLOODPLAIN REVIEW Approved
12/14/2001 JOE LINVILLE LANDSCAPE REVIEW Denied Revise the landscape plan to address Zoning and Engineering comments.

A 10' street landscape border is required along Ajo way, based on the MS&R right of way line. The plan appears to show a future landscape border; where is the current landscape border? A minimum 10' landscape area (unpaved) must be provided. Clearly show the correct MS&R right of way line on all plans.

If the required landscape border is located temporarilly within the MS&R right of way, an approved site plan is required indicating how the project will comply with LUC requirements when the MS&R right of way can no longer be used as part of the site. This plan is to be an exhibit to an executed covenant stating the responsibility of property owner, successor, or assignee as to the removal of improvements and compliance with the LUC at no cost to the City. The covenant is required prior to permit issuance. LUC 2.8.3.4.C,
LUC 2.8.3.5. Clearly show and identify the future landscape border on the site plan.

The site plans shows paving in the area identified as 10' street landscape. Remove paving from landscape areas. LUC 3.7.2.4

Two additional canopy trees are required in the nothern interior landscape border. LUC 3.7.2.4

The site plan indicates a 30" high screen wall, while the landscape plan shows a 5' high wall along Ajo Way. Revise all plans to provide consistent information.

Correct spelling errors on the Plant Materials legend.

Revise landscape note on sheet 2 to read water harvesting area. Clearly show these areas on the plan. LUC 3.7.4.3
12/14/2001 JOE LINVILLE NPPO REVIEW Passed no expansion of existing development.

Final Status

Task End Date Reviewer's Name Type of Review Description
02/07/2002 TGRIFFU1 OUT TO CUSTOMER Completed