| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 01/28/2002 | LAITH ALSHAMI | ENGINEERING | REVIEW | Denied | 1- Size the proposed rip rap pads in the drainage report and show the dimensions on the site plan. 2- Show the dumpster pad dimensions (DS 2-02.2.1.32). 3- Provide the width of the western ingress (DS 2-02.2.1.11). 4- Show existing and future right of way for Avenida Los Reyes (DS 2-02.2.1.19). 5- Show the P12xx-xxx number and any other applicable numbers such as rezoning case number (DS 2-02.2.1.31). 6- According to the drainage report, Basin "B" id a detention basin, not retention. Please revise as anecessary. Also provide the proposed basins dimensions and elevations (i.e. provide the basins construction details). 7- Drainage report comments: a- Figure 2 is missing. b- It is not clear what figure 3 is showing. Please clarify. c- Provide an offsite watershed map. d- It appears that detention basin "A" encroaches on the erosion setback line. Revise. e. The discharge point for detention basin "B" does not match existing conditions. Revise. f- Provide the detention basins design and routing calculations for onsite runoff only (i.e. do not combine it with offsite runoff) g- Provide a soils percolation test results which shows that retention is possible on this site. 8- Revise the site plan according to the drainage report revisions and show the exact location of the proposed retention basin. |
| 01/28/2002 | LAITH ALSHAMI | FLOODPLAIN | REVIEW | Denied | |
| 02/05/2002 | DAN CASTRO | ZONING | REVIEW | Denied | COMMENTS: Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed. CODE SECTION/ DEVELOPMENT STANDARD 1. Under the project data block on sheet TS1, revise 22nd Street required perimeter yard note to "the greater of 21 feet or height of exterior building wall from back of future curb." In addition, revise Avenida Los Reyes required street perimeter setback to "the greater of 21 feet or height of exterior building wall measured from back of future curb." D.S. 2-02.2.1.A.21/ L.U.C. 3.2.6.5.B.1 2. On sheet TS1, building square footage under project data block (9,455 SF.) does not match the building square footage under the lot coverage (9,732 SF). Revise for consistency. D.S. 2-02.2.2.A.3 3. All requested revisions must be made to the site plan, Landscape and NPPO plans. D.S. 2-07.2.1.A 4. Review of this plan by the Zoning Review Section may be done over the counter. Please contact Dan Castro to set an appointment. |
| 02/07/2002 | JOE LINVILLE | NPPO | REVIEW | Denied | SUBMIT REQUIRED COVENANT FOR REVIEW. LUC 3.8.6.4.b, DS 2-15.3.5 |
| 02/07/2002 | JOE LINVILLE | LANDSCAPE | REVIEW | Approved |