Permit Number: T01CM04846
Parcel: 120086800

Address:
4762 S 12TH AV

Review Status: Completed

Review Details: SITE

Permit Number - T01CM04846
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/27/2001 PHIL SEADER HANDICAP-SITE REVIEW Denied
09/28/2001 JIM EGAN FIRE REVIEW Approved
10/05/2001 BLANCA ESPINO SANITATION REVIEW Denied 7. 32. Refuse container location, size and access thereto fully dimensioned. A 20' alley is required. Please refer to D.S. 6-01.4.1.A-M, D.S. 6-01.4.2.A-D, D.S. 6-01.9.1 & 9.2 and D.S. 6-01.10.Exhibit I & II, Figures 1 & 2. I f you have any questions or need more information, you may want to contact Solid Waste Management at 791-3272.
10/05/2001 BLANCA ESPINO ENGINEERING REVIEW Denied D.S. 2-02.2.1 Site Plan
1. 5. Lot dimensions and bearings. Please identify property line and change line type to solid. Include bearings with dimensions.

2. 6. All existing and proposed buildings and structures, including location, size, height, overhangs, canopies and use. Please indicate if building is existing or proposed (new).

3. 10. Existing and future sight visibility triangles. Site plan needs to show svt's from the property onto 12th Ave.

4. 16. Drainage patterns, proposed finish floor elevation(s) and finish grades. Please show finish grades on future "Site Plan".

5. 17. Estimated cut and fill quantities. Please note if it is needed or not.

6. 20. All easements of record must be graphically shown on the plan together with recording docket and page reference. Please show alley's book & page number on future "Site Plan".

7. 32. Refuse container location, size and access thereto fully dimensioned. A 20' alley is required. Please refer to D.S. 6-01.4.1.A-M, D.S. 6-01.4.2.A-D, D.S. 6-01.9.1 & 9.2 and D.S. 6-01.10.Exhibit I & II, Figures 1 & 2. I f you have any questions or need more information, you may want to contact Solid Waste Management at 791-3272.
10/05/2001 BLANCA ESPINO FLOODPLAIN REVIEW Denied
10/12/2001 DAN CASTRO ZONING REVIEW Denied COMMENTS: Provide a response letter with the next site plan submittal that states how all the Zoning Review Section comments were addressed. CODE SECTION/ DEVELOPMENT STANDARD

1. a) Revise wheelstops to be two and one-half feet from the front of the parking space.
b) The back-up spur located near the south property line must have a minimum distance of three (3) feet between the back of spur and the property line. In addition, the back up spur must have a three (3) foot radius. Refer to D.S. 3-05.2.2.D for requirements. D.S. 2-02.2.1.A.8
D.S. 3-05.2.2.D

2. Per L.U.C. 3.3.7.8.A, a minimum of two Class II bicycle parking spaces are required. Revise bicycle parking calculation on sheet one (1) as required. D.S. 2-02.2.1.A.8
L.U.C. 3.3.7.8.A; D.S. 2-02.2.2.A.4

3. If applicable, provide a detail of proposed free standing signage and outdoor lighting on the site plan.
D.S. 2-02.2.1.A.13; D.S. 2-02.2.1.A.25

4. If applicable, all existing or proposed easements must be shown on the plan including width, type, and recording docket and page reference. D.S. 2-02.2.1.A.20

5. A) Add a note under the Zoning Information block on sheet 1 which states the existing use and proposed principal use of the site "Food Service, subject to L.U.C. 3.5.4.6.C and 3.5.13.5." D.S. 2-02.2.1.A.31

6. Add a general note which states that this project does not require a loading space. D.S. 2-02.2.2.A.5

7. All requested changes must be made to the site and landscape plans. D.S. 2-07.2.1.A
10/15/2001 PATRICIA GILBERT NPPO REVIEW Denied Please submit a Native Plant Preservation exception application, see attached documents.
10/17/2001 JOE LINVILLE LANDSCAPE REVIEW Denied 1. Include location map and legal description on the landscape plan. DS 2-07
2. Revise the note regarding the peruvian verbena, typically the plant grows to 3' wide. Show all individual plants at their projected sizes on the landscape plan. DS 2-07.2.2
3. Include quantities and symbols for all plants. DS 2-07.2.2
4. A five-foot masonry screen wall is required at the west property line (commercial use adjacent to R-2). Show the required wall on the site and landscape plan. LUC Table 3.7.2-I.
5. The refuse storage area must be screened with a six-foot masonry wall from residentially zoned property located within 100 feet. A six-foot high screen is required for the refuse storage area when located within 100 feet of adjacent commercial property. LUC Table 3.7.2-I. Revise the plans accordingly.
6. Dimension any portions of the right of way proposed to meet the 10' street landscape border requirement. City Engineer approval is required for any right of way landscaping. LUC 3.7.2.4.A.2
7. Detail 3 on sheet 2 does not appear to reflect a shrub planting detail, re-label or change detail as necessary. DS 2-07.
8. Within the vehicular use area, the minimum tree planter size is four feet wide and must contain a minimum unpaved area of 34 square feet. Dimension this area. Revise plans to remove concrete form this area. Bike rack detail shows concrete. Clarify on site and landscape plans where DG is used and where concrete is proposed. LUC 3.7.2.3.A
9. Remove the words present and existing from the landscape and site plans to avoid confusion. The labeling of the future plans is sufficient.
Integrate the site and landscape plans to provide for stormwater harvesting as indicated in the darinage statement prepared by J. Stanley dated August 6, 2000. Divert stormwater runoff to designated landscape areas. LUC 3.7.4.3.B.

Final Status

Task End Date Reviewer's Name Type of Review Description
10/31/2001 TAMI ACHONG OUT TO CUSTOMER Completed