10/16/2001 JIM EGAN FIRE REVIEW Approved
11/28/2001 PATRICIA GEHLEN ZONING REVIEW Denied CITY OF TUCSON DEVELOPMENT SERVICES DEPARTMENT
ZONING REVIEW SECTION

DATE: November 28, 2001
ACTIVITY NUMBER: T01CM04391
PROJECT NAME: Thayer Apartments
PROJECT ADDRESS: 272 East Calle Arizona
PROJECT REVIEWER: Patricia Gehlen

The following items must be revised on or added to the site plan. Please attach a response letter with the next submittal, which states how all Zoning Review Section comments regarding the Land Use Code and Development Standards were addressed:

1) Revise keynote 12 to read "…set 2.5' from sidewalk….to far side of bumper" Per DS 3-05.2.3.C.2 (DS 2-02.2.1.A.8),
2) The bicycle parking must be fully dimensioned per DS 2-09 (DS 2-02.2.1.A.9),
3) Please complete the western most sight visibility triangle (DS 2-02.2.1.A.10),
4) If applicable, please detail all proposed free-standing signage and outdoor lighting on the site plan (DS 2-02.2.1.A.13 & 25),
5) The proposed electrical easement must be recorded and the recordation information added to the site plan prior to approval (DS 2-02.2.1.A.20),
6) The lot coverage calculation must be revised to include the existing GFA to remain on site in the numerator (DS 2-02.2.2.A.3 and LUC 3.2.9),
7) The percent expansion calculation must be revised. The calculation is the proposed GFA less the existing GFA to be removed divided by the total existing GFA (DS 2-02.2.2.A.6),
8) Resubmittal of these plans is not required. Please call Patricia to schedule an over-the-counter review and approval at 791-5608. Remember to bring a copy of the originally submitted site plan.
12/11/2001 BLANCA ESPINO FLOODPLAIN REVIEW Denied
12/11/2001 BLANCA ESPINO ENGINEERING REVIEW Denied 1. Show Location map with a north arrow and a scale of 3" = 1 mile along with property description including Township, Range and Section.

2. Show location, size, height, overhangs, canopies and use for all existing and proposed buildings and structures.

3. Appropriately label all existing and future sight visibility triangles.

4. Location, type, size and height of existing and proposed signage if applicable.

5. Please show if street is "Public" or "Private".

6. All easements of record must be graphically shown on the plan together with recording docket and page reference if applicable.

7. The refuse container size and location do not meet code as per D.S. 6-01.2.2 & 4.0
12/11/2001 BLANCA ESPINO SANITATION REVIEW Denied
12/18/2001 PHIL SEADER HANDICAP-SITE REVIEW Approved
12/20/2001 JOE LINVILLE LANDSCAPE REVIEW Denied A minimum 5' masonry wall is required to screen portions of the vehicular use area (located within 100 feet) from adjacent residential properties. LUC Table 3.7.2-I Keynotes and callouts must be revised and the required screening elements must be shown on the site and the landscape plans.

The landscape border must be a minimum of 10' wide along the entire Calle Arizona street frontage. If a portion of the 10' is proposed within the right of way area, City Engineer approval is required prior to permit approval. Provide verification of approval for any portion of the border located in the right of way. Dimension any portion of the right of way used. LUC 3.7.2.4

Identify all plants and list quantities and sizes. 50% vegetative coverage and screening information is required for the street landscape border. Screen plantings do not count toward meeting the landscape coverage requirement. DS 2-07.2.2

An irrigation plan is required as part of this permit. Provide the required plan and revise the landscape note that indicates irrigation layout and specs will be provided prior to construction. DS 2-07
Additions to the landscape plan may be required pending review and approval of Native Plant Preservation. DS 2-15.3.4.B
12/20/2001 JOE LINVILLE NPPO REVIEW Denied Submit Native Plant Preservation plan or Application for Exception. LUC 3.8, DS 2-15

Final Status

Task End Date Reviewer's Name Type of Review Description
12/21/2001 CINDY AGUILAR OUT TO CUSTOMER Completed