08/21/2001 JIM EGAN FIRE REVIEW Denied FIRE SPRINKLERS REQUIRED.
08/24/2001 MIKE BERGHUIS SANITATION REVIEW Denied
08/24/2001 MIKE BERGHUIS ENGINEERING REVIEW Denied
08/24/2001 MIKE BERGHUIS FLOODPLAIN REVIEW Denied
09/05/2001 DAVID RIVERA ZONING REVIEW Denied
09/05/2001 PATRICIA GILBERT LANDSCAPE REVIEW Denied Street landscape border is required along 40th Street. Refer to LUC 3.7.2.4.A and DS 2-06.3.4.C.

Interior landscape borders are required, refer to LUC 3.7.2.4.B and DS 2-06.3.4.E.

When a development provides 4 or more parking spaces; one canopy tree is required for 15 parking spaces or a fraction thereof. Indicate compliance within the vehicle use area. Refer to LUC 3.7.2.3.

Areas where plants are susceptible to injury by vehicles or pedestrians require protection by appropiate means such as curbs, bollards or low walls. Indicate plant protection with landscape borders. LUC 3.7.2.3.B.

Provide a landscpe planting plan. Refer to 2-07.2.2.A.

Provide landscape maintenance notes. Refer to LUC 3.7.6. and DS 2-06.6.

Provide an irrigation plan. Refer to LUC 3.7.4.5. and DS 2-06.5.4.

Indicate the use of site stormwater runoff for supplemental irrigation purposes in landscaped areas. Refer to LUC 3.7.4.3.

Disturbed, grubbed, graded, or bladed area not improved shall be landscaped, reseeded or treated with an inorganic ground cover for dust control. Indicate the control of dust pollution. Refer to LUC 3.7.2.7.

Parking lots require a 5' screen for a non-MS&R street and a 5' wall adjacent to residential property. The development requires 5' screen along the east, west and south property lines. Refer to LUC Table 3.7.2.I and 3.7.3. and DS 2-06.3.7.
09/06/2001 PATRICIA GILBERT NPPO REVIEW Denied Native Plant Preservation plan approval is required. Submit a plan or an application for exception. Refer to LUC 3.8.
09/13/2001 DOUG LAAKSO HANDICAP-SITE REVIEW Denied PROVIDE SITE PLAN TO ADDRESSING ALL ACCESSIBILITY REQUIREMENTS OF THE IBC AND DEV. STDS. FOR SITE ACCESS.

Final Status

Task End Date Reviewer's Name Type of Review Description
09/17/2001 ELAINE ROSE OUT TO CUSTOMER Stop