Permit Review Detail
Review Status: Stopped
Review Details: RESIDENTIAL BLDG/ZONING/FLOOD/WWM
Permit Number - T01CM03836
Review Name: RESIDENTIAL BLDG/ZONING/FLOOD/WWM
Review Status: Stopped
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/03/2001 | MICHAEL ST. PAUL | ZONING | REVIEW | Approved | |
| 08/03/2001 | MICHAEL ST. PAUL | NPPO | REVIEW | Passed | |
| 08/03/2001 | JAMES TATE | FLOODPLAIN | REVIEW | Approved | |
| 08/14/2001 | REYES ARVAYO | BUILDING-RESIDENTIAL | REVIEW | Denied | 2000 IRC RESIDENTIAL CHECKLIST Date: 08-13-01 Re: Project No.T01CM03836 Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. SCOPE OF REVIEW: The scope of this review covers Architectural, Structural, Plumbing, Mechanical, Model Energy and Electrical codes. All code references are to the 2000 IRC. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval. FOUNDATION PLAN: 1. Note on the drawings the allowable soil bearing pressure used in the design of the footings, or state that the assumed value of 1500 psf is being used, per Table R401.4.1, a soils report is not required. It is up to the designer/homebuilder to be aware of the soil conditions of the site. If soil testing has been done, a copy of the soils report shall be submitted with the construction plans, and the foundation design shall reflect soils report recommendations. 2. Dimension the stem wall thickness, footing width thickness and depth into undisturbed soil for each footing type and condition, per Table R403.1. - 19" minimum; hollow concrete/masonry FLOOR PLAN: 1. Provide access to each separate attic and crawl space that exceeds 30 s.f.. Designate locations on the drawings. Openings shall not be less than 22" by 30". The attic access shall provide a minimum of 30"of headroom, and shall be located in a hallway or readily accessible space, per R807. STRUCTURAL PLANS: 1. Specify lateral support of trusses. 2. Detail gable end bracing connections. 3. Completely detail all connections and cross-reference to the foundation and framing plans: - Truss to beam ELEVATIONS: 1. Note and specify a complete roofing system: roofing type, grade of materials and method of installation per R905. 2. Note and specify all roof slopes appropriate to material (see R905). 3. Show calculation of attic ventilation area in compliance with R806.2. Note location of all vents needed to comply. SECTIONS - DETAILS - MISC. NOTES: 1. On standard detail sheets, remove all details that do not apply or are not used. 2. Cross-sections shall be cross-referenced to the floor plan and framing plans. PLUMBING PLANS: 1. Note on plans: Plumbing shall comply with Chapters 24 through 30.. 2. Water Lines: Provide total fixture demand and maximum developed length per P2903, Tables P2903.6 and P2903.7. 3. Plumbing layout doesn't match plot plan sewer location. 4. Gas meter location on site plan doesn't match plumbing plan MECHANICAL PLANS: 1. Note on plans: Mechanical shall comply with Chapters 12 through 24, 2000 IRC. ELECTRICAL PLANS: 1. Note on plans: Electrical work shall comply with Chapters 33 through 42, 2000 IRC. MODEL ENERGY CODE: 1. Provide Energy Calculations per IECC, or comply with IRC Chapter 11. 2. Call out on the plans the "R" values of insulation, as well as the "U" values of the windows and doors in conformance with the energy calculations provided. REVIEWED BY REYES ARVAYO 791-5550 EXT. 113 |
| 08/15/2001 | GERRY KOZIOL | WWM | REVIEW | Denied |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 09/06/2002 | ELAINE ROSE | APPROVAL SHELF | Stop |
| 08/17/2001 | ANY | OUT TO CUSTOMER | Stopped |
| 08/15/2001 | ANY | REJECT SHELF | Stopped |