Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T01CM03747
Parcel: 123070540

Review Status: Completed

Review Details: RESIDENTIAL BLDG/ZONING/FLOOD/WWM

Permit Number - T01CM03747
Review Name: RESIDENTIAL BLDG/ZONING/FLOOD/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/06/2001 MICHAEL ST. PAUL ZONING REVIEW Approved
09/06/2001 MICHAEL ST. PAUL NPPO REVIEW Passed
09/06/2001 TOM WEIDEMAN FLOODPLAIN REVIEW Approved
09/10/2001 REYES ARVAYO BUILDING-RESIDENTIAL REVIEW Denied 2000 IRC RESIDENTIAL CHECKLIST
Date: 09-11-01
Re: Project No. T01CM03747


Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed.

SCOPE OF REVIEW:

The scope of this review covers Architectural, Structural, Plumbing, Mechanical, Model Energy and Electrical codes. All code references are to the 2000 IRC. All features were checked only to the extent allowed by the submittals provided. All portions of this project are assumed to meet or will meet other departmental requirements, conditions and concerns before permit approval.

FLOOR PLAN:

1. Note that bath tub and shower enclosures shall be finished per P2710 with ceramic tile, or a listed enclosure, to a height of 72" above the drain per R702.4 and R307.2.

ELEVATIONS:

1. Note and size all roof drains or scuppers on flat-roofed areas per R903.4 and IPC.

SECTIONS - DETAILS - MISC. NOTES:

1. On standard detail sheets, cross out all details that do not apply or are not used.

2. Cross-sections shall be cross-referenced to the floor plan and framing plans.

PLUMBING PLANS:

1. Note on plans: Plumbing shall comply with Chapters 24 through 30..

2. Water Lines: Provide total fixture demand and maximum developed length per P2903, Tables P2903.6 and P2903.7.

3. Provide pressure and temperature relief valve at water heater, per P2803.

4. Plumbing for washer ?drain ,co. ect. Ect.

ELECTRICAL PLANS:

1. Note on plans: Electrical work shall comply with Chapters 33 through 42, 2000 IRC.

2. Designate the circuit for washer and dryer provide panel schedule noting circuit number and size, along with a general description.

3. Note that at least one 20-amp branch circuit shall be installed to serve the laundry room, and this circuit shall have no other outlets, per E3603.3 and E3801.8.

4. Note that light fixtures in clothes closets shall be installed in accordance with E3903.11..


REVIEWED BY REYES ARVAYO 791-5550 EXT. 113
09/11/2001 GERRY KOZIOL WWM REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
09/17/2001 JKOZUCH OUT TO CUSTOMER Completed