Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T01CM03637
Parcel: 125010810

Address:
2704 E 8TH ST

Review Status: Completed

Review Details: RESUBMITTAL

Permit Number - T01CM03637
Review Name: RESUBMITTAL
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
09/27/2001 DAVE WILLETT BUILDING-RESIDENTIAL REVIEW Denied PLAN CHECK COMMENTS - PROJECT #T01CM03637 REVISED 09/27/01

PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN.

SCOPE OF REVIEW:

THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2000 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL.

GENERAL REQUIREMENTS:

1. PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES.


FOUNDATION:

1. PROVIDE A FOUNDATION PLAN FOR THE PORCH ADDITION.

STRUCTURAL:

1. PROVIDE A COMPLETE ROOF FRAMING PLAN OF THE PORCH ADDITION. SHOW SIZE, SPACING AND SPAN OF ALL FRAMING MEMBERS, RAFTERS, BEAMS & LEDGERS.

2. COMPLETELY DETAIL ALL CONNECTIONS AND CROSS-REFERENCE TO THE FOUNDATION AND FRAMING
PLANS FOR THE PORCH ADDITION.

- BEAM TO POST
- POST TO SLAB
- LEDGERS TO MASONRY, LEDGERS TO FRAME, FRAME TO LEDGERS
- JOIST TO LEDGER, JOIST TO BEAM
- HANGER TYPES


PLUMBING PLANS:

1. GAS LINE APPEARS TO BE INADEQUATE SIZE PER SECT. 1217 AND TABLE 12-3 IN THE 1994 UPC. INCLUDE IN TOTAL DEVELOPED LENGTH, THE LENGTH VERTICAL DISTANCE FROM THE METER TO THE ATTIC AND FROM THE ATTIC TO THE WATER HEATER/ FURNACE. ADD TO TOTAL LENGTH. SHOULD BE APPROX. 80'. REVISE PIPE SIZES BASED ON TABLE 12-3.

ELECTRICAL:

1. SHOW THE LOCATION OF WHERE THE ELECTRIC PANEL IS TO BE MOVED TO ON THE PLOT PLAN AND ELECTRIC PLAN.

MISCELLANEOUS

1. PROVIDE STRUCTURAL ENGINEERING FOR YARD WALLS OVER 6' HIGH.

2. PLOT PLAN NEEDS TO BE APPROVED BY PLANNING AND FLOODPLAIN AGAIN FOR YARD WALL AND PORCH ADDITION.

IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER:
DAVE WILLETT @ 791-5550 EXT. 110

Final Status

Task End Date Reviewer's Name Type of Review Description
09/28/2001 CINDY AGUILAR OUT TO CUSTOMER Completed