Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING/FLOOD/WWM
Permit Number - T01CM03637
Review Name: RESIDENTIAL BLDG/ZONING/FLOOD/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/24/2001 | PATRICIA GEHLEN | ZONING | REVIEW | Approved | |
| 07/24/2001 | PATRICIA GEHLEN | NPPO | REVIEW | Passed | |
| 07/24/2001 | DOUG WILLIAMS | FLOODPLAIN | REVIEW | Approved | |
| 07/27/2001 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 08/27/2001 | DAVE WILLETT | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T01CM03637 08/28/01 PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN. SCOPE OF REVIEW: THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2000 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL. GENERAL REQUIREMENTS: 1. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 2. PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. 3. REVISE ALL CODE REFERENCES ON ALL SHEETS TO THE CURRENT CODES SITE PLAN: 1. CONFLICT IN PLANS: COVERED PORCH SHOWN ON SITE PLAN DOESN'T RUN FULL LENGTH OF HOUSE BUT ON THE ELECTRICAL PLAN IT SHOWS A FAN SUPPORTED BY THE EXISTING ROOF OUTSIDE A ROOM AT THE REAR OF THE HOUSE . CLARIFY. 2. SHOW THE LOCATION OF THE SPA IN RELATIONSHIP TO THE HOUSE. SPECIFY IF SPA IS TO BE INCLUDED IN THIS PERMIT. PREFAB TYPE SPA'S CAN BE INCLUDED BUT IN GROUND TYPE REQUIRE SEPARATE PERMIT. FLOOR PLANS: 1. LABEL ALL ROOMS AND SPACES. SHOW ALL DOORS. 2. DESIGNATE THE LOCATIONS OF REQUIRED TEMPERED GLASS PER R308.4. 3. ARE ANY WALLS BEING REMOVED ON THE INTERIOR BEARING WALLS ? CLARIFY. PLUMBING PLANS: 1. GAS LINE APPEARS TO BE INADEQUATE SIZE PER SECT. 1217 AND TABLE 12-3 IN THE 1994 UPC. PROVIDE THE LENGTH OF LINE TO EACH APPLIANCE & TOTAL DEVELOPED LENGTH FROM METER TO MOST REMOTE APPLIANCE ON THE SYSTEM PER UPC 1217.2 2. NOTE ON PLANS THAT SHOWER AND TUB / SHOWER COMBINATIONS THAT HAVE INDIVIDUAL CONTROL VALVES SHALL BE OF THE PRESSURE BALANCE OR THERMOSTATIC MIXING VALVE TYPE. IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: DAVE WILLETT @ 791-5550 EXT. 110 NOTE: AS OF 2-02-01 THE CITY OF TUCSON HAS ADOPTED THE 2000 IRC EXCEPT FOR THE PLUMBING PORTION WHICH IS THE STATE PLUMBING CODE. ALL PLANS SHALL BE REFERENCE TO THE PREVIOUSLY MENTIONED CODES. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 07/27/2001 | MONICA VALDEZ | OUT TO CUSTOMER | Completed |