Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Number: T01CM02942
Parcel: 137053190

Review Status: Completed

Review Details: RESIDENTIAL BLDG/ZONING/FLOOD/WWM

Permit Number - T01CM02942
Review Name: RESIDENTIAL BLDG/ZONING/FLOOD/WWM
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/13/2001 PETER MCLAUGHLIN ZONING REVIEW Approved
06/13/2001 PETER MCLAUGHLIN NPPO REVIEW Passed
06/13/2001 DOUG WILLIAMS FLOODPLAIN REVIEW Approved
08/01/2001 DAVE WILLETT BUILDING-RESIDENTIAL REVIEW Denied PLAN CHECK COMMENTS - PROJECT #T01CM02942 08/01/01

PLAN REVIEW FOR THE ABOVE REFERENCED STRUCTURE HAS BEEN COMPLETED. THIS LETTER REFLECTS COMMENTS TO BE ADDRESSED. IN ORDER TO FACILITATE A SHORTER BACK CHECK TIME, WE REQUEST THAT YOU PLEASE PROVIDE REVISED PLANS AND CALCULATIONS, HIGHLIGHTING ANY CHANGES, ALONG WITH A WRITTEN RESPONSE TO EACH OF THE NOTED ITEMS INDICATING ACTION TAKEN.

SCOPE OF REVIEW:

THE SCOPE OF THIS PLAN REVIEW COVERS ARCHITECTURAL, PLUMBING, MECHANICAL, MODEL ENERGY AND ELECTRICAL CODES. ALL CODE REFERENCES ARE TO THE 2000 IRC AND STATE PLUMBING CODE. ALL FEATURES WERE CHECKED ONLY TO THE EXTENT ALLOWED BY THE SUBMITTALS PROVIDED. ALL PORTIONS OF THIS PROJECT ARE ASSUMED TO MEET OR WILL MEET OTHER DEPARTMENTAL REQUIREMENTS, CONDITIONS AND CONCERNS BEFORE PERMIT APPROVAL.

GENERAL REQUIREMENTS:

1. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS OR (1) SEPIA & (1) BLUE LINE SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS.

2. PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES.


FLOOR PLANS:

1. SHOW COMPLIANCE WITH R310 PROVIDING EGRESS FROM BEDROOM #2. THIS ROOM DOES NOT HAVE ANY EGRESS DIRECTLY TO THE OUTSIDE AND CANNOT BE USED AS A BEDROOM. REVISE PLAN.



STRUCTURAL PLANS:

1. 1-HOUR FIRE WALL BETWEEN THE UNITS IS REQUIRED TO GO TO THE BOTTOM OF THE ROOF SHEATHING. REVISE SECTION B-1 TO SHOW HOW THIS WILL BE ACHIEVED.

2. APS POST BASE IS INADEQUATE TO SUPPORT THE LOAD OF THE ROOF AT THE CENTER POST IN THE PORCH. PROVIDE A POST BASE CAPABLE OF SUPPORTING A LOAD OF 6000# MINIMUM. SPECIFY MANUFACTURE AND MAKE.


MECHANICAL PLANS:

1. GAS WATER HEATER SHALL COMPLY WITH COMBUSTION AIR REQUIREMENTS. DETAIL HOW.


ELECTRICAL PLANS:

1. REVISE PANEL SCHEDULE SHOWING CIRCUIT NUMBERS. DRYER SHOULD BE CIRCUIT 5&7 AND WATER HEATER SHOULD BE CIRCUIT 2&4.

2. SUBMIT ELECTRICAL RISER DIAGRAM. DUPLEX'S REQUIRE A DUAL PACK TYPE PANEL.


IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER:
DAVE WILLETT @ 791-5550 EXT. 110
08/02/2001 GERRY KOZIOL WWM REVIEW Approved

Final Status

Task End Date Reviewer's Name Type of Review Description
08/16/2001 JKOZUCH OUT TO CUSTOMER Completed