Permit Number: T01CM02807
Parcel: 129020740

Review Status: Completed

Review Details: COMMERCIAL TI

Permit Number - T01CM02807
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
06/07/2001 JIM EGAN FIRE REVIEW Approved
06/07/2001 HOLLY PEARCE PLUMBING-COMMERCIAL REVIEW Denied
06/07/2001 DOUG LAAKSO BUILDING-COMMERCIAL REVIEW Denied S1) COMBINE INTO A SINGLE SUITE FOR PERMITTING. . ........ S2) CHECK ADDRESSING W/ PIMA COUNTY ADDRESSING FOR SUITE ADDRESS COMBO. .... . .............................................. S3) PROVIDE VALUATION TO CONSTRUCT PROJECT ON APPLICATION. . ................................................................................. S4) CLARIFY ONE-HOUR FIRE-RATED CORRIDOR REQUIREMENTS PER IBC TABLE 1004.3.2.1, FULLY DETAIL ON PLANS AND PROVIDE LISTING TO JUSTIFY DETAILS AND CONNECTIONS TO ADJACENT CONSTRUCTION. . . .................. S5)PROVIDE COMPLETE DRAWINGS SHOWING ALL REQUIRED WORK TO COMPLY WITH IBC.. .................................. S6) DETERMINE AND DOCUMENT IF THIS IS A CHANGE OF OCCUPANCY ,PER IBC, AS THIS MAY INCREASE/CHANGE CODE REQUIREMENTS,ie: FULL CONFORMANCE WITH CURRENT CODE.. . .......................................................................... S7) PROVIDE REVISED, ORIGINAL AND COMPLETED CODE REVIEW CHECKLIST. . . ................................................................... S8) CLARIFY ACCESSIBILITY REQUIREMENTS PER IBC CHAPTER 11 AND 34, SHOW COMPLIANCE ON PLANS (FULL COMPLIANCE vs 20% SPENT ON ACCESSIBILITY). . ................. S9) PROVIDE DETAILS OF NEW CONSTRUCTION , INCLUDING CONNECTIONS TO STRUCTURE ABOVE AND BELOW, CALLOUT FASTENERS( TYPE, SIZE SPACING/NUMBER). . . .................................................................. S10) FULLY DIMENSION ACCESSIBLE TOILET FACILITIES AND SHOW CLEAR AREAS AT DOOR, CROSS-SECTION THROUGH LAVATORY.
06/07/2001 DOUG WILLIAMS FLOODPLAIN REVIEW Approved
06/07/2001 DAN CASTRO ZONING REVIEW Approved
06/07/2001 HOLLY PEARCE MECHANICAL-COMMERCIAL REVIEW Denied
06/07/2001 BOB SUBA ELECTRICAL-COMMERCIAL REVIEW Denied
07/17/2001 SREEVES WWM REVIEW Passed

Final Status

Task End Date Reviewer's Name Type of Review Description
07/17/2001 SUE REEVES OUT TO CUSTOMER Completed