Review Status: Completed
Review Details: SITE
Permit Number - T01CM02612
Review Name: SITE
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 07/10/2001 | JIM EGAN | FIRE | REVIEW | Approved | |
| 07/18/2001 | JOE LINVILLE | NPPO | REVIEW | Approved | Cl. 1 exception based 1998 aerial photo. |
| 07/18/2001 | JOE LINVILLE | LANDSCAPE | REVIEW | Denied | 1. The landscape border along Olsen Avenue must comply with the requirements of LUC 3.7 based on the expansion of the site.///// 2. Include existing landscaping proposed to meet code requirements on the landscape plan.///// 3. Indicate the treatment existing or proposed for all ground surfaces. Per LUC 3.7.2.7 all areas of the site, if not developed, must be landscaped, reseeded, or treated with an appropriate inorganic dust control material such as decomposed granite or decorative rock. ///// 4. The Olsen Avenue right of way area between the property line and the existing curb must be treated with an appropriate dust control material per LUC 3.7.2.4.A.3///// 5. Screening is required for refuse storage areas per 3.7.2-I. Locate any storage areas on the site and landscape plans and provide screening as indicated in the table. 6. The vehicle use area must include barriers to prevent vehicular travel to unpaved portions of the site, to prevent injury to landscaping, etc. Include barriers such as curbing, fencing, etc. between the vehicular use area and other portions of the site per DS 3-05.2.3.C and LUC 3.7.2.7.//// 7. An interior landscape border is required along the entire south property line. Revise plan to include 1 canopy tree for every 33 feet of property line per LUC 3.7.2.4.///// 8. Include notes or details regarding required stormwater harvesting within the landscaped areas per LUC 3.7.4.3.B///// 9. A water conserving irrigation system is required for all new landscape plantings. Include this information on the plan. |
| 07/23/2001 | DAVID RIVERA | ZONING | REVIEW | Denied | |
| 07/26/2001 | MATT FLICK | ENGINEERING | REVIEW | Approved | |
| 07/29/2001 | MATT FLICK | FLOODPLAIN | REVIEW | Approved | Elevation Certificate per Floodplain Use Permit #1238 must be returned and approved by the City Engineer prior to Final Inspection or Certificate of Occupancy. |
| 07/29/2001 | MATT FLICK | SANITATION | REVIEW | Approved | |
| 07/29/2001 | PHIL SEADER | HANDICAP-SITE | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 10/26/2001 | JKOZUCH | OUT TO CUSTOMER | Completed |