Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T01CM02268
Review Name: COMMERCIAL TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/10/2001 | PATRICIA GEHLEN | ZONING | REVIEW | Passed | |
| 05/10/2001 | DOUG WILLIAMS | FLOODPLAIN | REVIEW | Approved | |
| 05/18/2001 | JIM EGAN | FIRE | REVIEW | Approved | |
| 05/21/2001 | HOLLY PEARCE | PLUMBING-COMMERCIAL | REVIEW | Passed | |
| 05/21/2001 | HOLLY PEARCE | MECHANICAL-COMMERCIAL | REVIEW | Passed | |
| 05/22/2001 | BOB SUBA | ELECTRICAL-COMMERCIAL | REVIEW | Passed | |
| 06/18/2001 | DOUG LAAKSO | BUILDING-COMMERCIAL | REVIEW | Denied | MEZZANINE....................................................................6/18 /01..... T01CM02268...................................................................................... 1. CLARIFY OCCUPANCY / OCCUPANCIES PER 2000 IBC, COORDINATE DRAWING T-0.1 WITH CODE REVIEW CHECKLIST . . .................................................................................... 2. CLARIFY AND JUSTIFY ALLOWABLE AREA WITH CALCULATIONS PER IBC. . ............................................................. 3. PROVIDE : " COMMERCIAL PLAN SUBMITTAL CHECKLIST" AND " CODE REVIEW CHECKLIST" SIGNED BY ARCHITECT OF RECORD. . . ................................................................................. 4. SEPARATE BUILDING PERMITS REQUIRED FOR SHELVING OVER EIGHT FEET HIGH, IBC SEC # 1621.2.8 AND # 1622.3.4. . . ...................................................................................... 5. PROVIDE COPY OF SOILS REPORT FOR REVIEW. . ............. 6. CLARIFY DESIGN PER IBC , DO NOT MIX CODES , ie: UBC, REVISE CALCULATIONS. . . . .......................................................... 7. PROVIDE STRUCTURAL CALCULATIONS AND DETAILS FOR GUARDRAILS. . . ...................................................................... 8. fULLY DETAIL AND SPECIFY MEZZANINE.ie: SHOP DRAWINGS AND CALCULATIONS BY REGISTRANT AND APPROVED BY ARCHITECT OR ENGINEER OF RECORD. . ...... 9. PROVIDE SPECIAL INSPECTION FOR : . ................................ .......1. HIGH STRENGTH BOLTING................................................. .......2. FIELD WELDING. . .. ............................................................. .......3. SHOP WELDING . ................................................................ .......4. DRILLED IN ANCHOR BOLTS. |
| 06/19/2001 | GERRY KOZIOL | WWM | REVIEW | Passed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 06/25/2001 | DELMA ROBEY | OUT TO CUSTOMER | Completed |