Permit Number: T01CM02245
Parcel: 111051290

Review Status: Completed

Review Details: SITE

Permit Number - T01CM02245
Review Name: SITE
Review Status: Completed
Review Date Reviewer's Name Type of Review Description Status Comments
05/18/2001 JIM EGAN FIRE REVIEW Approv-Cond
05/31/2001 DAVID RIVERA ZONING REVIEW Denied
06/13/2001 JOE LINVILLE NPPO REVIEW Denied Submit Native Plant Preservation Plan
06/13/2001 JOE LINVILLE LANDSCAPE REVIEW Denied 1. Water harvesting is required in the landscape areas. Provide information on how this will be accomplished. LUC 3.7.4.3.B.
2. Identify all existing vegetation. DS 2-07.2.2
3. Vehicle use areas must include barriers, such as
curbing. DS 3-05.2.3. Landscape planters and borders must be protected from vehicular damage. LUC 3.7.2.3.B. Indicate on the site and landscape plans the required barriers and plant protection.
4. The refuse storage location must be buffered from
Blacklidge Drive with a 10' street landscape border and
screened with a 6' wall. Table LUC 3.7.2-I
5. A 5' masonry wall is required along portions of the east
and west property lines where the vehicle use area is
located adjacent to residentially zoned property.
Table LUC 3.7.2-I
6. Add a note to the plans indicating that all mechanical equipment will be screened entirely form view along the street frontage and provide screening as appropriate. LUC Table 3.7.2-I.
7. Provide the following calculations on the landscape plan:
square footage of the site, square footage of the vehicle
use area, square footage of landscaped areas and
calculation for 50% coverage of the street border.
8. Revise symbols used on the landscape plan to correspond
with the landscape materials legend. Currently the symbols
do not match.
9. Interior landscape borders are required along the east and west property lines. Where vehicle use areas are located
adjacent to the property lines an equivalent number of trees must be placed between the property line an the building or principal use. 3.7.2.4.B.3
10. A minimum of one tree is required within the vehicle use area. LUC 3.7.2.3.
06/15/2001 TOM WEIDEMAN FLOODPLAIN REVIEW Denied
06/15/2001 TOM WEIDEMAN ENGINEERING REVIEW Denied
06/15/2001 TOM WEIDEMAN SANITATION REVIEW Denied
06/15/2001 PHIL SEADER HANDICAP-SITE REVIEW Denied

Final Status

Task End Date Reviewer's Name Type of Review Description
10/01/2001 DELMA ROBEY OUT TO CUSTOMER Completed