Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T01CM02121
Review Name: COMMERCIAL TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 05/02/2001 | MICHAEL ST. PAUL | ZONING | REVIEW | Approved | |
| 05/02/2001 | DOUG WILLIAMS | FLOODPLAIN | REVIEW | Approved | |
| 05/04/2001 | JIM EGAN | FIRE | REVIEW | Approved | |
| 05/07/2001 | HOLLY PEARCE | PLUMBING-COMMERCIAL | REVIEW | Approved | Plumbing 1. Show on the plan how the water heater installation will comply with Sec511.2 UPC 1994 Az. Code. 2. Complete the water demand calculations on the plan. Take NOTE: Waste fixture units under the Az. Code will be per Table 7-3, ie; W.C. = 6fu. |
| 05/07/2001 | HOLLY PEARCE | MECHANICAL-COMMERCIAL | REVIEW | Denied | Mechanical 1. Architect needs to identify all rated walls on hte plan. If rated corridors are required, show on the plan. will the ceiling/roof be required to be rated? If so- show on the plan and show how it is to be constructed. 2. Show on the plan how the mech. design will comply with Chapter 4 IMC 2000. 3. Condensate shall discharge in an approved location Sec307.2.1 IMC 2000. NOTE: 1982 UMC not used anymore. |
| 05/08/2001 | RANDY SCHULER | ELECTRICAL-COMMERCIAL | REVIEW | Denied | E1 1) Panels LB, LC, and the 75kVA transformer lack proper work clearance. 99NEC 110-26 2) Provide a roof top gfci receptacle within 25' of HP's 18 and 19. 3) It appears circuit LA 26,28, 30 should be 24, 26, 28. 4) Provide a disconnect for the hot water heaters circuits LA 33-35 and LA 37-39 or provide a circuit breaker that is lockable in the off position. 99NEC 422 part C 5) Provide a circuit for the re-circulating pump above the electric room. Provide a disconnect for both re-circulating pumps. Note a plug and cord connection cannot be utilized above the ceiling. 99NEC 400-8(5), 430-101 6) Provide the fuse and disconnect size for all HP units. A legend based upon unit numbers is preferable to marking adjacent to each disconnect. 7) Provide conduit and wire size for HP's 14 and 15, circuit HB 7-9-11. E2 1) Describe the light fixtures including the ballast loads. 2) Provide a load in the panel for circuit HA-25. E3 1) General note #1 should reference the 99NEC and note 9 should reference section 250-122. E4 1) Provide a #8 bonding wire within the conduit from the transformer secondary to panel LV. 99NEC 250-30(a) 2) Provide a complete one- line service diagram. Include the total number of disconnects, service lateral size, load on each gutter and total service load. 3) Provide fault current analysis to panel HA. 4) Reference to the grounding electrode system for separately derived systems on the one-line should be 250-30. General notes. 1) Provide IEC lighting budget calculations. 2) Please return the plans I have already reviewed along with your next submission. |
| 05/24/2001 | DOUG LAAKSO | BUILDING-COMMERCIAL | REVIEW | Denied | 1. PROVIDE COMPLETED CODE REVIEW CHECKLIST ATTACHED, BY ARCHITECT OF RECORD. .................................. 2. CLARIFY FIRE-STOPPING OF CONCEALED AREA BETWEEN FURRING AND CMU EXTERIOR WALL FROM AFES TO UTILITY ROOM. .......................................................................... 3. EXPLAIN AND SHOW , ON DRAWINGS, DOOR LOCKS AND LATCHED , HOW THEY FUNCTION TO MEET CODE REQUIREMENTS PER IBC SEC #1003.3.1.8. ................................ 4. CLARIFY LANDING COMPLIES WITH IBC SEC #1003.3.1.4 (LEVEL), AND SEC #1003.4.5. ......................................................... 5. CLARIFY RAMP COMPLIANCE ON DRAWING 3/10 PER IBC SEC 1003.3.4 W/LANDINGS TOP AND BOTTOM OF RAMP. ....... 6.SHOW COMPLIANCE WITH IBC SEC 11: ................................... .............1. FACILITY COMPLIANCE PER SEC 1102 . .................... .............2. SHOW COMPLIANCE WITH REQUIREMENTS OF THIS SECTION. ................................................................................. 7. PROVIDE DETAILS FOR NEW STUCCO EXTERIOR WALLS INCLUDING CONNECTION TO STRUCTURE ABOVE AND BELOW, REF 3/10, IBC SEC 14,25,etc. ........................................... 8. PROVIDE STRUCTURAL CALCULATIONS AND DETAILS FOR SUPPORT OF NEW ROOFTOP MOUNTED UNITS REF DWG 10/10, SHOW SPAN OF JOISTS AND BEAMS ON DRAWINGS. ....................................................................................... 9. CLARIFY MINIMUM PLUMBING FIXTURES REQUIRED OCCUPANT LOAD FROM CHAPTER 10 DIVIDED BY NUMBER OF OCCUPANTS PER FIXTURE FROM CHAPTER 29,TABLE 2901.1 YIELDS MINIMUM NUMBER OF PLUMBING FIXTURES. PROVIDE REQUIRED NUMBER OF FIXTURES. ........................... 10. WHERE ARE HEIGHTS OF EDF SPECIFIED? PER P2 OF 3, REMARKS. SPECIFY PER ACCESSIBILITY, IBC CHAP 11, ICC/ANSI A117.1 CHAP 6 SEC 602. SHOW COMPLIANCE, DWG 8/10. ................................................................................................... 11. CLARIFY CONNECTION AND FASTENERS USED FOR ATTACHMENT TO STRUCTURE ABOVE 1/8 AND PARTITION AT LATERAL BRACING DETAIL, STRUCTURE ABOVE IS WOOD JOISTS W/PLYWOOD AND BRACING IS LIGHT GAGE STUDS AND TRACK ( NOT APPROPRIATE WITH ICBO ER #2388 OR #4780),REVISE FASTENERS. SHOW FASTENER TYPE, SIZE SPACING/NUMBER. ................................................... 12. LOCATE NEW OPENING A/8 ON FLOOR PLAN , DWG #3. ... 13. PROVIDE REVISED STRUCTURAL CALCULATIONS AT OPENING A/8 TO ADDRESS :..................................... ................. ............1. JAMB REINFORCING FROM FOUNDATION TO BOND BEAM AT JOIST BEARING .............................................................. ...........2. BEARING AT JAMBS ON MASONRY . ............................ 14. PROVIDE STRUCTURAL ANALYSIS ADDRESSING "SEISMIC USE GROUP" DUE TO CHANGE OF OCCUPANCY PER IBC SEC 16, TABLES 1604.5, 1616.3, SHOW BUILDING IS IN COMPLIANCE. |
| 05/31/2001 | GERRY KOZIOL | WWM | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 06/20/2001 | JKOZUCH | OUT TO CUSTOMER | Completed |