Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T01CM02086
Review Name: COMMERCIAL TI
Review Status: Completed
Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
---|---|---|---|---|---|
05/01/2001 | JIM EGAN | FIRE | REVIEW | Approved | |
05/01/2001 | HOLLY PEARCE | PLUMBING-COMMERCIAL | REVIEW | Passed | |
05/01/2001 | DOUG LAAKSO | BUILDING-COMMERCIAL | REVIEW | Denied | S1) CLARIFY ACCESSIBILITY PER 2000 IBC CHAP 11 & 3408, WHERE IS 20% SPENT ON ACCESSIBILITY. ............................. S2) TYPE OF CONSTRUCTION V-1HR - NO LONGER IN 2000 IBC, SEE TABLE 601 = VB. .............................................................. S3) CALLOUT FASTENERS USED TO ATTACH TOP OF PARTITIONS TO STRUCTURE ABOVE, INCLUDING BRACING TO JOIST CONNECTION, WITH TYPE, SIZE, SPACING/ NUMBEROF FASTENERS, REF DET AA/A2............... .................. S4) CALLOUT CEILING SUSPENSION SYSTEM, ON DRAWINGS DET 1/A2, MANUFACTURER`S NAME AND MODEL NUMBER. .... |
05/01/2001 | DOUG WILLIAMS | FLOODPLAIN | REVIEW | Approved | |
05/01/2001 | PETER MCLAUGHLIN | ZONING | REVIEW | Approved | |
05/01/2001 | HOLLY PEARCE | MECHANICAL-COMMERCIAL | REVIEW | Passed | |
05/01/2001 | RANDY SCHULER | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
05/07/2001 | JKOZUCH | WWM | REVIEW | Needs Review |
Final Status
Task End Date | Reviewer's Name | Type of Review | Description |
---|---|---|---|
05/07/2001 | JKOZUCH | OUT TO CUSTOMER | Completed |