Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T01CM01904
Review Name: COMMERCIAL TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/20/2001 | DAN CASTRO | ZONING | REVIEW | Approved | |
| 04/20/2001 | DOUG WILLIAMS | FLOODPLAIN | REVIEW | Approved | |
| 04/23/2001 | BOB SUBA | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 04/23/2001 | HOLLY PEARCE | PLUMBING-COMMERCIAL | REVIEW | Approved | |
| 04/23/2001 | JIM EGAN | FIRE | REVIEW | Denied | 1. PROVIDE OCCCUPANT LOAD CALCULATIONS BASED ON 2000 IBC TABLE 1003.2.2.2.(EXERCISE ROOMS) 2. PROVIDE OCCUPANCY SEPARATIONS BASED ON 2000 IBC SECTION 302.3. |
| 04/23/2001 | HOLLY PEARCE | MECHANICAL-COMMERCIAL | REVIEW | Approved | |
| 04/24/2001 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 05/11/2001 | DOUG LAAKSO | BUILDING-COMMERCIAL | REVIEW | Denied | 1. CLARIFY SEPARATION REQUIREMENTS ON DRAWINGS PER IBC TABLE #302.3.3 AND SEC 302. ....................................... 2. PROVIDE CONSTRUCTION DETAILS FOR SEPARATIONS. . 3. PROVIDE LISTINGS, ON DRAWINGS, FOR SEPARATIONS AND PENETRATIONS, ETC.. .......................................................... 4. CHANGE OF OCCUPANCY FROM M- RETAIL TO A3 GYM REQUIRES TI TO MEET CURRENT CODE IBC.. .......................... 5. PROVIDE EXIT OCCUPANT LOAD CALCULATIONS PER IBC SEC #10, ON DRAWINGS AND CODE REVIEW CHECKLIST. ...... 6. PROVIDE EXITS PER IBC CHAP #10, OCCUPANT LOAD. ...... 7. PROVIDE EXIT SIGNS PER IBC CHAP #10. ............................. 8.REVERSE SWING OF #108a INTO MASSAGE ROOM OR OTHERWISE REVISE TO COMPLY WITH CHAP #10 AND #11 OF IBC ,SEE SEC #1003.2.3.1. ........................................................ 9. SPECIFY DOOR HARDWARE ON DRAWINGS TO SHOW COMPLIANCE WITH IBC CHAP #10, INCLUDING PANIC HARDWARE. ..................................................................................... 10. CLARIFY CORRIDOR FIRE-RATING REQUIREMENTS PER IBC SEC #1004, APPEARS TO REQUIRE ONE-HOUR CORRIDOR PER TABLE #1004.3.2.1,FULLY DETAIL AND PROVIDE LISTINGS ON DRAWINGS. ........................................... 11. DEFINE MINIMUM AISLE WIDTHS PER IBC #1008.7. ........... 12. SHOW CONFORMANCE ON DRAWINGS TO IBC CHAP #11 ACCESSIBLITY. ........................................................................ 13. SHOW CONFORMANCE FOR ACCESSIBLE ROUTE PER IBC SEC #1104, ENTRANCES PER SEC #1105, PARKING PER SEC #1106. ....................................................................................... 14. FULLY DETAIL ACCESSIBLE TOILET ROOM/S PER IBC SEC # 1108, INCLUDING CLEAR FLOOR SPACE, WHEELCHAIR ACCESSIBLE COMPARTMENT, SEE ANSI A 117.1-1998 FOR DIMENSIONING AND FIXTURE LOCATIONS, AS WELL AS DOOR REQUIREMENTS. ............................................................... 15. EXPLAIN HOW MASSAGE CONFORMS TO TUCSON CODE REQUIREMENTS SEE EXCERPT ATTACHED. ............................ 16. PROVIDE MINIMUM PLUMBING FACILITIES PER IBC SEC #29 : .................................................................................................. .........1. SEPARATE FACILITIES FOR MALE AND FEMALE COMPLING WITH SEC #2902.2 AND #2902.3. ............................... .........2. CLARIFY EMPLOYEE FACILITIES REQUIRED PER IBC SEC #2902.2. ..................................................................................... 17. CLARIFY CONFORMANCE WITH IBC SEC #3408. ................. |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 05/16/2001 | JKOZUCH | OUT TO CUSTOMER | Completed |
| 05/14/2001 | MONICA VALDEZ | OUT TO CUSTOMER | Completed |