Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL NEW
Permit Number - T01CM01474
Review Name: COMMERCIAL NEW
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/28/2001 | JIM EGAN | FIRE | REVIEW | Denied | |
| 04/09/2001 | PETER MCLAUGHLIN | ZONING | REVIEW | Denied | |
| 05/09/2001 | JKOZUCH | FLOODPLAIN | REVIEW | Denied | |
| 05/16/2001 | HOLLY PEARCE | PLUMBING-COMMERCIAL | REVIEW | Denied | Plumbing 1.Provide the size of the existing sewer on the sheet C-1.1 at each segment of the line. NOTE: Waste fixture units for water closets will be 6 fu (ea) in the 1994 UPC Az. Code. 2. F.F.E. should be on sheet C-1.1. 3. A kitchen sink in a commercial application is 3fu. 4. Provide a water demand calculation based on Appendix A UPC 1994 Az. Code. 5. Provide an expansion tank on the water heater Per Sec608.3 Par 3 UPC 1994 Az. Code. |
| 05/16/2001 | HOLLY PEARCE | MECHANICAL-COMMERCIAL | REVIEW | Denied | Mechanical 1. Model Energy Code calculations not with plan set. 2. Show on the plan how the mech. design complies with Chapter 4 IMC 2000. 3. Combustion Air shall be obtained from outside Per Sec 507.3.1 UPC 1994 Az. Code. NOTE: The ceiling can not exceed 16" above the top of the door. The grills in the door shall have a free air opening of 130 sq. in. each opening. 4. Ahood will be required over the range Per Sec 507.2.2 IMC 2000. Make-up air shall comply with Sec 508 IMC 2000. |
| 05/23/2001 | PHIL SEADER | BUILDING-COMMERCIAL | REVIEW | Denied | |
| 05/24/2001 | WATER | WATER | REVIEW | Approved | |
| 05/29/2001 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 06/16/2001 | RANDY SCHULER | ELECTRICAL-COMMERCIAL | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 05/30/2001 | JKOZUCH | REJECT SHELF | Completed |
| 05/29/2001 | DELMA ROBEY | OUT TO CUSTOMER | Completed |