Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T01CM01386
Review Name: COMMERCIAL TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/27/2001 | JIM EGAN | FIRE | REVIEW | Approved | |
| 03/27/2001 | CAGUILAR | ZONING | REVIEW | Needs Review | |
| 04/16/2001 | HOLLY PEARCE | PLUMBING-COMMERCIAL | REVIEW | Denied | |
| 04/16/2001 | DOUG WILLIAMS | FLOODPLAIN | REVIEW | Approved | |
| 04/16/2001 | HOLLY PEARCE | MECHANICAL-COMMERCIAL | REVIEW | Denied | |
| 04/18/2001 | BOB SUBA | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 04/30/2001 | DOUG LAAKSO | BUILDING-COMMERCIAL | REVIEW | Denied | 1. PROVIDE COMPLETED CODE REVIEW CHECKLIST FOR BUILDING REMODEL ADDRESSING: ............................................. ........MEZZANINE - DORM -- OCCUPANT LOAD ........................... ........MAIN FLOOR - DORM-- OCCUPANT LOAD ........................... ........MAIN DINING -- OCCUPANT LOAD ........................... ........OFFICE AREA -- OCCUPANT LOAD .......................... ........SMALL DINING -- OCCUPANT LOAD........................... 2. SUBMIT COMPLETE DESIGN DRAWINGS AND STRUCTURAL CALCULATIONS SEALED BY AN ARIZONA REGISTRANT AND APPROVED BY THE ARCHITECT OF RECORD OR MAKE APPLICATION FOR A SEPARATE BUILDING PERMIT FOR THE CANOPY. ........................................ 3. PROVIDE COMPLETED CODE REVIEW CHECKLIST FOR THE CANOPY. .................................................................................. 4.PROVIDE / VERIFY 42" GUARDRAIL CONFORMING TO UBC SEC 509, AT MEZZANINE. ............................................................... 5. CLARIFY ACCESSIBILITY PER UBC SEC #1110, #1111, #1112, SHOW BY ESTIMATE ON DRAWINGS, WHERE 20% OF THE VALUE OF THIS PROJECT IS SPENT ON ACCESSIBLITY. 6. PROVIDE FIRE-RATING DETAILS FOR THE CHASE AND HOOD AREA W/ FIRE LISTINGS ON THE DRAWINGS TO JUSTIFY FIRE-RATINGS. ................................................................ 7. PROVIDE STRUCT8URAL CALCULATIONS AND DETAILS FOR: ................................................................................................... ..........1. SUPPORT OF HOOD AND CHASE .................................. ..........2. LATERAL ANALYSIS ......................................................... ..........3. COLUMNS ........................................................................... ..........4. FOUNDATIONS .................................................................. ..........5. JAMB TO LINTEL/ HEADER ............................................. ..........6. NEW WALL TO EXISTING WALL ...................................... ..........7. CEILING OVER ROOMS #101 AND #102 ........................ ..........8. CEILING JOISTS TO WALL ............................................... ..........9. CEILING JOISTS TO EXISTING WALL ............................. ........10. CONNECTION OF INTERIOR WALL TO CEILING ........... ........11. CONNECTION OF WALL TO FLOOR SLAB W/ PRESERVATIVE PRESSURE TREATED BOTTOM PLATE. |
| 05/04/2001 | GERRY KOZIOL | WWM | REVIEW | Denied |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 05/21/2001 | CINDY AGUILAR | OUT TO CUSTOMER | Completed |