Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T01CM00138
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/09/2001 | TERRY STEVENS | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T01CM00138 2/5/01 2ND REVIEW 3/9/01 Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating the action taken. GENERAL REQUIREMENTS: 1. All plans shall be legible and a scale no smaller than ΒΌ-inch = 1-foot 0-inches shall be used for all floor plans, framing plans and elevations. Details at a minimum 3/8-inch scale. 2. All corrections and revisions shall be made on the original tracings. Return all redlined prints. The final package shall consist of two sets of drawings and related documents, one which the City shall retain and the other set will be stamped and returned to you. 3. To avoid delays, ensure all corrections have been made, are complete and have been coordinated on all applicable details and notes. STRUCTURAL PLANS: 1. Completely detail all connections and cross-reference to the foundation and framing plans: - Rafters to top plate - Rafters to girder truss or beam - Collar ties required at min. 4' oc in bottom 2/3 of rise SECTIONS - DETAILS - MISC. NOTES: 1. Provide a complete building cross-section. More than one may be required to clearly illustrate how the structure is built. 2. Cross-sections shall be cross-referenced to the floor plan and framing plans. PLUMBING PLANS: 1. Note and specify all piping materials. MECHANICAL PLANS: 1. The dwelling must be provided with heating capable of maintaining a room temperature of 68 degrees at a point 3' above the floor, per R303.6. INDICATE LOCATION OF DUCT WORK ELECTRICAL PLANS: 1. A receptacle outlet shall be provided adjacent to the basin in each bathroom, per E3801.6. Bathroom outlets shall be on a separate 20-amp circuit with no other outlets, per E3603.4.. IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: TERRY STEVENS: @ 791-5550 EXT. 112 |
| 03/12/2001 | TGRIFFUS | WWM | REVIEW | Denied |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 03/14/2001 | MVALDEZ | OUT TO CUSTOMER | Completed |