Permit Review Detail
Review Status: Completed
Review Details: GRADING
Permit Number - T01BU03285
Review Name: GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 12/06/2001 | LAITH ALSHAMI | ENGINEERING | REVIEW | Denied | 1- Provide a copy of the approved drainage report. 2- The 5' wall openings are shown in a location different from what is shown on the site plan. Justify the new location. 3- Provide details of the retentionarea (dimensions, slopes, elevations, etc.) 4- Provide contour lines or spot elevations within 25' outside the proerty lines. 5- Provide cut and fill quantities. 6- Demonstrate offsite drainage acceptance if applicable. 7- Show all the slopes and wall footing (within property lines) on x-section "A". 8- Provide basis of elevation and basis of bearing. Provide City of Tucson bench mark datum with book and page. 9- Show the P.A.A.L dimensions. 10- Dimension the landscaped area in the front and provide curb return radii. 11- Dimension the dumdster enclosure, the curb dimensions and the curb return radius north of the dumpster. 12- Demonstrate that the 24" curb break has capacity to accommodate drainage. 13- Provide the dimensions, including the curb return radius, of the curb west of the parking area. |
| 12/06/2001 | LAITH ALSHAMI | FLOODPLAIN | REVIEW | Denied | |
| 12/07/2001 | MSTPAUL | NPDES | REVIEW | Passed | |
| 12/07/2001 | PATRICIA GILBERT | NPPO | REVIEW | Approved | An approved NPPO exception per PGilbert on 10/2/01. |
| 12/07/2001 | MICHAEL ST. PAUL | ZONING | REVIEW | Denied |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/11/2001 | MONICA VALDEZ | OUT TO CUSTOMER | Completed |