Permit Review Detail
Review Status: Completed
Review Details: GRADING
Permit Number - T01BU02371
Review Name: GRADING
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 08/27/2001 | TOM WEIDEMAN | ENGINEERING | REVIEW | Denied | DATE: August 27, 2001 FROM: Engineering Section SUBJECT Barrio Viejo Elderly Housing Site Plan T01BU02317 COMMENTS: The Grading Plan has been reviewed and is not acceptable. Please address the following comments. 1. Provide details of all the catch basins and grates being used, specifically construction keynotes # 23b, 24a, 24b and 25. 2. It appears keynote #3 being shown along the north boundary referencing the 12" pipe should read keynote #33. 3. Should the second catch basin south of South Rubio, invert 92.35, be referencing keynote 24a instead of 24b? 4. Call out if South Rubio will be closed off at the north property line. 5. It appears keynote #13 shown just south of the retention catch basin is incorrectly referencing rip-rap at a sidewalk scupper. 6. All the harvesting areas as shown on the site plan should not have drainage piping attached as this defeats the purpose of water harvesting. Make the appropriate corrections to the harvesting areas per site plan comment #9. Correct construction keynote #28 accordingly. 7. Indicate piping to the catch basin or "other areas as shown on the plans" in typical detail #9, the roof downspout. 8. Back of sidewalk curbing should be shown in typical detail #6, access ramp as appropriate to each ramp. 9. Item #1 under the grading notes should call out the International Building Codes (IBC), Chapter 36. 10. Provide an administrative address for the site. 11. Provide appropriate sheet numbers. Items Required: Revised Grading Plan Re-submittal Required: Yes If you have any questions on the above comments feel free to call Tom Weideman at 791-4942. My E-mail address is tweidema@ci.tucson.az.us. |
| 08/27/2001 | DAVID RIVERA | ZONING | REVIEW | Denied | |
| 08/27/2001 | TOM WEIDEMAN | FLOODPLAIN | REVIEW | Denied | DATE: August 27, 2001 FROM: Engineering Section SUBJECT Barrio Viejo Elderly Housing Site Plan T01BU02317 COMMENTS: The Grading Plan has been reviewed and is not acceptable. Please address the following comments. 1. Provide details of all the catch basins and grates being used, specifically construction keynotes # 23b, 24a, 24b and 25. 2. It appears keynote #3 being shown along the north boundary referencing the 12" pipe should read keynote #33. 3. Should the second catch basin south of South Rubio, invert 92.35, be referencing keynote 24a instead of 24b? 4. Call out if South Rubio will be closed off at the north property line. 5. It appears keynote #13 shown just south of the retention catch basin is incorrectly referencing rip-rap at a sidewalk scupper. 6. All the harvesting areas as shown on the site plan should not have drainage piping attached as this defeats the purpose of water harvesting. Make the appropriate corrections to the harvesting areas per site plan comment #9. Correct construction keynote #28 accordingly. 7. Indicate piping to the catch basin or "other areas as shown on the plans" in typical detail #9, the roof downspout. 8. Back of sidewalk curbing should be shown in typical detail #6, access ramp as appropriate to each ramp. 9. Item #1 under the grading notes should call out the International Building Codes (IBC), Chapter 36. 10. Provide an administrative address for the site. 11. Provide appropriate sheet numbers. Items Required: Revised Grading Plan Re-submittal Required: Yes If you have any questions on the above comments feel free to call Tom Weideman at 791-4942. My E-mail address is tweidema@ci.tucson.az.us. |
| 09/11/2001 | PATRICIA GILBERT | NPPO | REVIEW | Denied | An approved site plan is required. Pre-permit inspection is required to schedule please call, 791-5550 ext. 118. |
| 09/25/2001 | CAGUILAR | NPDES | REVIEW | Passed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 09/26/2001 | TAMI ACHONG | OUT TO CUSTOMER | Completed |