Permit Review Detail
Review Status: Completed
Review Details: RESUBMITTAL
Permit Number - T00CM05667
Review Name: RESUBMITTAL
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 04/27/2001 | DOUG LAAKSO | BUILDING-COMMERCIAL | REVIEW | Denied | T00CM05667R - 311 E. CONGRESS ST DGL 5/2/01 1. INDICATE LOCATION OF ONE-HOUR OCCUPANCY SEPARATION BETWEEN A-3 ( BANQUET ROOM) AND R-1 (HOTEL). .......................................................................................... 2. PROVIDE AND DETAIL ONE-HOUR FIRE-RATED PROTECTION AT OPENINGS IN ONE-HOUR OCCUPANCY SEPARATION, INCLUDING ONE-HOUR FIRE-RATED DOOR ASSEMBLIES ( DOORS, DOOR FRAMES, DOOR CLOSERS), ONE-HOUR FIRE-RATED WINDOW ASSEMBLIES, FIRE DAMPERS AT DUCT PENETRATIONS AND FIRE PROTECTION AT OTHER PENETRATIONS. ................................ 3. SEE PRIOR COMMENT #1.3.SHOW COMPLIANCE. ................ 4. SEE PRIOR COMMENT #1.4, DOOR, DOOR FRAME AND CLOSER TO BE 20 MINUTE FIRE- RATED, MINIMUM. ................ 5. SEE PRIOR COMMENT #1.5. ...................................................... 6. PROVIDE RESPONSE LETTER SEALED AND SIGNED BY ARCHITECT OF RECORD. |
| 04/27/2001 | JIM EGAN | FIRE | REVIEW | Denied | |
| 04/30/2001 | HOLLY PEARCE | MECHANICAL-COMMERCIAL | REVIEW | Passed | |
| 04/30/2001 | HOLLY PEARCE | PLUMBING-COMMERCIAL | REVIEW | Passed | |
| 05/01/2001 | BOB SUBA | ELECTRICAL-COMMERCIAL | REVIEW | Passed |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 05/04/2001 | MONICA VALDEZ | OUT TO CUSTOMER | Completed |