Permit Review Detail
Review Status: Completed
Review Details: COMMERCIAL TI
Permit Number - T00CM05592
Review Name: COMMERCIAL TI
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/16/2000 | JIM EGAN | FIRE | REVIEW | Approved | |
| 11/16/2000 | DOUG WILLIAMS | FLOODPLAIN | REVIEW | Approved | |
| 11/28/2000 | RANDY SCHULER | ELECTRICAL-COMMERCIAL | REVIEW | Approved | |
| 11/29/2000 | HOLLY PEARCE | PLUMBING-COMMERCIAL | REVIEW | Approved | |
| 11/29/2000 | HOLLY PEARCE | MECHANICAL-COMMERCIAL | REVIEW | Approved | |
| 11/30/2000 | CGROSS | ZONING | REVIEW | Denied | |
| 12/11/2000 | DOUG LAAKSO | BUILDING-COMMERCIAL | REVIEW | Denied | 1. SHOW OCCUPANCY OF EACH ADJACENT TENANT SPACE 1/A1, INCLUDING OCCUPANCY SEPARATIONS. 2. CLARIFY OCCUPANCY OF TENANT SPACE ROOM #104 , APPEARS TO BE 'S' OCCUPANCY, REF DWG #A1. 3. JUSTIFY 1-HOUR WALL REF 1/A1 , W1. 4. PROVIDE DOCUMENTATION FOR STORAGE ROOM #104 AND TINT ROOM #101 TO CLARIFY OCCUPANCY. 5. STAMP ON DWGS RE: BUILDING PERMIT FOR STORAGE RACKS OVER 8' HIGH. 6.SHOW WHERE 20% OF THE PERMIT VALUATION ($40,000) IS SPENT ON ACCESSIBILITY PER UBC CHAP 11, SEC 1110 & SEC 1112. 7. JUSTIFY ONE TOILET FACILITY PER UBC CHAP 29, APPENDIX CHAP 29, AND TABLE A29A, PROVIDE 2 ACCESSIBILE TOILETS. 8. JUSTIFY CYLINDER LOCK AT STORAGE ROOM EXIT DOOR WHICH HAS PANIC HARDWARE, REF: A1, UBC SEC 1004 AND UBC STD 10-4. 9. PROVIDE COPY OF LISTING ON DRAWINGS AND COMPLYING CONSTRUCTION DETAILS FOR FIRE RATED ASSEMBLIES IE: FIRE RATED WALLS. 10. FULLY DETAIL CEILING SUSPENSION SYSTEM/S ON DRAWINGS OR PROVIDE NAME AND MODEL NUMBER OF MANUFACTURER/S ON DRAWINGS. 11. CLARIFY INSULATION CONFORMS WITH UBC SEC 707, FLAME-SPREAD RATING NOT TO EXCEED 25 AND SMOKE DENSITY NOT TO EXCEED 450. 12. SHOW HARDWARE ON EXISTING EXIT DOORS CONFORM TO REQUIREMENTS OF UBC SEC #10 & #11. 13. CLARIFY EXIT SIGNAGE ON EXISTING EXIT DOORS, PER UBC SEC 10, REF DRAWING A1. 14. SHOW CONNECTIONS OF WALLS TO STRUCTURE ABOVE AND BELOW 4/A1 & 5/A1, INCLUDING FASTENERS (TYPE, SIZE, SPACING/NUMBER ) AND BRACING. 15. PROVIDE OFFICIAL ADDRESS SLIP FROM PIMA COUNTY ADDRESSING - COMBINING ADJACENT SUITES INTO A SINGLE SUITE. 16. PROVIDE STRUCTURAL ENGINEER'S SEAL & SIGNATURE ON DRAWING #A1, DETAIL #3. 17. CLARIFY STRUCTURAL ANALYSIS: 1. ADDRESS LATERAL PARALLEL TO WALL WITH OPENING. 2. SHOW REINFORCING AND GROUTING OF WALL TO COMPLY WITH UBC SEC 2106.1.12.3. 3. ADDRESS LOADING ON TRUSSES. 4. ADDRESS LOADING ON 3 x 6 PLATE (3). 18. PROVIDE INSPECTION PROGRAM PER UAC SEC 302.5. 19. SPECIAL INSPECTION REQUIRED FOR : 1. EXPANSION ANCHORS 2. EPOXY ANCHORS 3. MASONRY GROUTING AND REINFORCING 4. FIELD WELDING. 20. SPECIAL INSPECTION STAMPS WILL BE PLACED ON DRAWINGS. |
| 12/12/2000 | CBUFORD | WWM | REVIEW | Approved |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 01/05/2001 | TAMI ACHONG | REJECT SHELF | Completed |
| 01/05/2001 | TAMI ACHONG | APPROVAL SHELF | Completed |
| 12/12/2000 | TAMI ACHONG | OUT TO CUSTOMER | Completed |