Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING/FLOOD/WWM
Permit Number - T00CM05515
Review Name: RESIDENTIAL BLDG/ZONING/FLOOD/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 11/13/2000 | DOUG WILLIAMS | FLOODPLAIN | REVIEW | Approved | |
| 11/14/2000 | DRIVERA | NPPO | REVIEW | Passed | |
| 11/14/2000 | DAVID RIVERA | ZONING | REVIEW | Approved | |
| 12/04/2000 | TERRY STEVENS | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T00CM05515 12/5/00 PLEASE ADDRESS THE FOLLOWING COMMENTS. RESUBMIT TWO SETS OF CORRECTED PLANS. SUBMIT A COPY OF THIS LETTER , NOTING THE DETAIL AND OR SHEET WHERE THE CORRECTION MAY BE FOUND. GENERAL REQUIREMENTS 1. ALL CORRECTIONS AND REVISIONS SHALL BE MADE ON THE ORIGINAL TRACINGS AND TWO NEW SETS OF PRINTS SHALL BE RETURNED ALONG WITH ALL REDLINE PRINTS. 2. PEN OR PENCIL CORRECTIONS ON FINAL PRINTS WILL NOT BE ACCEPTABLE. TO AVOID DELAYS ENSURE ALL CORRECTIONS HAVE BEEN MADE, ARE COMPLETE AND HAVE BEEN COORDINATED ON ALL APPLICABLE DETAILS AND NOTES. FOUNDATION PLAN 1. NOTE ON THE DRAWINGS THE ALLOWABLE SOIL BEARING PRESSURE USED IN THE DESIGN OF THE FOOTINGS, OR STATE THAT THE ASSUMED VALUE OF 1,000 PSF IS BEING USED. FLOOR PLAN 1. SHOW COMPLIANCE WITH UBC SEC 1203.2 PROVIDING NATURAL LIGHT INTO ROOMS. MISSING FOR BEDROOM #1-----ADJACENT WALL MUST BE MORE THAN 50% OPEN 2. SHOW COMPLIANCE WITH UBC SEC 1203.3 PROVIDING NATURAL VENTILATION. MISSING FOR BEDROOM #1-----ADJACENT WALL MUST BE MORE THAN 50% OPEN 3. SHOW COMPLIANCE WITH UBC SEC 310.4 PROVIDING EGRESS FROM BEDROOMS OR BASEMENTS. SHOW MAXIMUM SILL HEIGHT OF 44". MISSING FOR BEDROOM #1-----ADJACENT WALL MUST BE MORE THAN 50% OPEN TO USE WINDOW OF DRESSING ROOM FOR EGRESS WINDOWS IN BEDROOMS #4 & #5 DO NOT MEET MIN. REQUIREMENTS---- HORIZONTAL OPENING MIN. 20" 4. PROVIDE ACCESS TO EACH SEPARATE ATTIC AND CRAWL SPACE. DESIGNATE LOCATIONS ON THE DRAWINGS. OPENINGS SHALL NOT BE LESS THAN 22"X30" THE LOCATION OF THE ATTIC ACCESS SHALL PROVIDE A MINIMUM OF 30" OF HEADROOM. UBC SEC 1505.1----------SEE MECH. PLAN 5. MIN. WIDTH OF A HABITUAL ROOM IS 7'------BEDROOM #4 DOES NOT MEET THIS CODE REQUIREMENT. ELEVATIONS 1. NOTE AND SPECIFY ALL ROOF SLOPES. MINIMUM ROOF SLOPE 3/8" PER FOOT. UBC SEC 1506.1 AND LOCAL AMENDMENT. NOTE: PORCH ROOF SLOPE APPEARS TO BE FLAT IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: TERRY STEVENS: @ 791-5550 EXT. 112 |
| 12/06/2000 | RAY MORGAN | WWM | REVIEW | Denied |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 12/11/2000 | CLAUDIA BUFORD | APPROVAL SHELF | Passed |
| 12/11/2000 | CLAUDIA BUFORD | OUT TO CUSTOMER | Passed |
| 12/07/2000 | CLAUDIA BUFORD | REJECT SHELF | Passed |