Permit Review Detail
Review Status: Completed
Review Details: RESIDENTIAL BLDG/ZONING/FLOOD/WWM
Permit Number - T00CM05499
Review Name: RESIDENTIAL BLDG/ZONING/FLOOD/WWM
Review Status: Completed
| Review Date | Reviewer's Name | Type of Review | Description | Status | Comments |
|---|---|---|---|---|---|
| 03/22/2001 | DAN CASTRO | ZONING | REVIEW | Approved | |
| 03/22/2001 | DCASTRO | NPPO | REVIEW | Passed | |
| 03/27/2001 | GERRY KOZIOL | WWM | REVIEW | Approved | |
| 03/27/2001 | JIM JOHNSEN | FLOODPLAIN | REVIEW | Approved | |
| 04/05/2001 | TERRY STEVENS | BUILDING-RESIDENTIAL | REVIEW | Denied | PLAN CHECK COMMENTS - PROJECT #T00CM05499 4/5/01 Plan review for the above referenced structure has been completed. This letter reflects comments to be addressed. In order to facilitate a shorter back check time, we request that you please provide revised plans and calculations, highlighting any changes, along with a written response to each of the noted items indicating the action taken. GENERAL REQUIREMENTS: 1. All corrections and revisions shall be made on the original tracings. Return all redlined prints. The final package shall consist of two sets of drawings and related documents, one which the City shall retain and the other set will be stamped and returned to you. SITE PLAN: 1. Provide dimensions from all structures to property lines, and show distances between all structures. Note: Min. distance between two single family residences is 6' [assumed property lines] with out a one hour rated firewall. It appears a firewall is required between existing porch and new house and between existing and new carports. FOUNDATION PLAN: 1. Footing widths for one-story, per Table R403.1: - 19" minimum; hollow concrete/masonry STRUCTURAL PLANS: 1. Center 6x10 HF SS at carport appears to be inadequate-------change or submit calcs. 2. Include complete details of required firewalls. ELEVATIONS: 1. Show calculation of attic ventilation area in compliance with R806.2. Note location of all vents needed to comply. SECTIONS - DETAILS - MISC. NOTES: 1. Note and specify the size, spacing and length of embedment of anchor bolts for sill plates, top plates and ledgers. PLUMBING PLANS: 1. Provide pressure and temperature relief valve at water heater, per P2803. 2. Waste line as indicated in or under footing is not allowed as per UPC. 3. Waste vent missing for tub/shower. MODEL ENERGY CODE: 1. Provide Energy Calculations per IECC, or comply with IRC Chapter 11. 2. Call out on the plans the "R" values of insulation, as well as the "U" values of the windows and doors in conformance with the energy calculations provided. IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT YOUR ASSIGNED PLANS EXAMINER: TERRY STEVENS: @ 791-5550 EXT. 112 |
Final Status
| Task End Date | Reviewer's Name | Type of Review | Description |
|---|---|---|---|
| 04/12/2001 | MONICA VALDEZ | OUT TO CUSTOMER | Completed |